Device functions
Seite 22
UPT-6010
Version 2
8.2
PROFINET communication
The following sections only describe controller-specific functions. For general information on the PROFINET inter-
face and the system configuration, please refer to the description of your PLC.
The PROFINET interface of the UPT-6010 supports "Conformance Class C" with IO/RT and IRT according to IEC
61784-2.
The controller can communicate via the PROFINET interface provided the 24 VDC supply voltage (terminals 5+7)
is present.
As long as no line voltage is present, the controller remains in an inactive status.
But interruption of the line voltage (e.g. by being switched off when a door is opened) triggers the error message
201 (error group no. 7, network voltage/sync signal is missing) and the Alarm relay switches. This is caused by
the lack of line voltage. The error message can be reset by switching on the line voltage again and setting the
RS bit (
section 8.5.3 "Reset (RS)" on page 25).
You can easily process the error code that appears if the line voltage is switched off – or suppress switching of
the alarm relay – in the PLC program.
8.3
Device master file (GSDML)
The configuring tools for the PROFINET controller interpret the content of the device master files (GSDML) and
use this information to create a parameter set for the PROFINET controller which controls user data traffic. The
GSDML-V2.35-ROPEX-0150-UPT-6010-20190520.XML
file of the UPT-6010 contains all essential controller
information for the configuration, e.g. the I/O data description, parameter descriptions, error messages etc. The
HEAT
(yellow)
—
START requested
but function blocked (e.g.
AUTOCAL active, set tem-
perature < 40 °C)
START executing
OUTPUT
(green)
In control mode, luminous intensity is proportional to heating current.
ALARM
(red)
Configuration error, no
AUTOCAL possible
Controller calibrated incor-
rectly, run AUTOCAL
Error,
section 8.19
DATA EXCHANGE
(red / green)
—
Rotary coding switches for
device name set to 0xFF
(factory setting restored)
Green: Communication
with PROFINET controller
is active
Red: Internal error in
PROFINET module
BUS FAILURE
(red / green)
Blinks (red)
for 3 s at 2 Hz:
No data exchange
Blinks (green or yellow)
at 2 Hz:
DCP signal service activated via bus
Red: No communication or
slow / no physical connec-
tion
LINK PORT 1, 2
(green)
—
—
Connection exists to
Ethernet
RX / TX PORT 1, 2
(yellow)
Device is transmitting / receiving Ethernet frames
LED
Blinks slowly (1 Hz)
Blinks fast (4 Hz)
Lit continuously