Device functions
Version 2
UPT-6010
Seite 21
8
Device functions
See also section 6.6 "Wiring diagram (standard)" on page 14.
8.1
LEDs and controls
In addition to the functions shown above, the LEDs also indicate various controller operating states. These states
are described in detail in the table below:
LED
Blinks slowly (1 Hz)
Blinks fast (4 Hz)
Lit continuously
AUTOCAL
(yellow)
RS bit set (reset)
AUTOCAL requested but
function blocked (e.g.
START active)
AUTOCAL executing
LED blinks at a different frequency:
Supply voltages incorrect (too low)
12 13 14 15 16 17 18
9
8
6
5
10
11
7
4
3
2
1
P2
P1
Rx
Tx
Rx
Tx
LI
N
K
LI
N
K
BUS FAILURE
(red/green
LED)
(red/green
LED)
µC POWER
DATA EXCH
(green LED)
(green LED)
24 V POWER
Lit (green) while data exchange
with PROFINET controller.
Lit or blinking if no connection
exists to PROFINET.
Lit if external 24 VDC power
supply is present.
Lit if internal power supply for
PROFINET interface is OK.
AUTOCAL
(yellow LED)
(yellow LED)
HEAT
(red LED)
(green LED)
ALARM
OUTPUT
Lit during heating phase.
Lit or blinking to indicate fault.
Indicates pulses in
measurement mode. In control
mode, luminous intensity is
proportional to heating current.
Lit while AUTOCAL process is
executing.
RX/TX
(yellow LED)
LINK
(green LED)
Lit or blinking if Ethernet
frames are transmitted.
Lit if connection exists to
Ethernet.
OUTPUT
HEAT
ALARM
BUS FAILURE
DATA EXCHANGE
µC POWER
24VDC POWER
AC
!