Factory settings
Version 2
UPT-6010
Seite 51
9
Factory settings
The CIRUS
®
UPT-6010 temperature controller is configured at the factory as follows:
Internal device fault / no line
voltage
- Hardware fault (replace controller)
- Jumper for alarm relay not connected or incorrectly con-
nected
- No line voltage
Rotary coding switch
for
heating element alloy
and
temperature range
Heatsealing element alloy: 1700 ppm/K
Temperature range: 300 °C
Rotary coding switch: "0" position
Slide switch
for
alarm relay
Alarm relay energized at alarm
Temperature
diagnosis
Temperature diagnosis: Off
Heatup
timeout
Heatup timeout: Off
Fault area
Explanation
Possible causes
0