Device functions
Seite 32
UPT-6010
Version 2
resistances are available from index 17. At index 16 the value of the passes through the current transformer is
available. This value can also be written and will be stored remanently in the controllers memory with every
change. The correct calculation of the absolute calibration resistances is only possible if the real count of wire
passes through the current transformer is given in this parameter.
The indices 16 to 48 are first available as from firmware 303.
Index
Function
Default value
Value range
0/1
Calibration deviation, channel 0 (in 0.01%)
0
-100.00%…100.00%
2/3
Calibration deviation, channel 1 (in 0.01%)
0
-100.00%…100.00%
4/5
Calibration deviation, channel 2 (in 0.01%)
0
-100.00%…100.00%
6/7
Calibration deviation, channel 3 (in 0.01%)
0
-100.00%…100.00%
8/9
Calibration deviation, channel 4 (in 0.01%)
0
-100.00%…100.00%
10/11
Calibration deviation, channel 5 (in 0.01%)
0
-100.00%…100.00%
12/13
Calibration deviation, channel 6 (in 0.01%)
0
-100.00%…100.00%
14/15
Calibration deviation, channel 7 (in 0.01%)
0
-100.00%…100.00%
16
Passes through current transformer
1
1…9
17/18
Calibration resistance, channel 0 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
19/20
Calibration resistance, channel 1 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
21/22
Calibration resistance, channel 2 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
23/24
Calibration resistance, channel 3 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
25/26
Calibration resistance, channel 4 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
27/28
Calibration resistance, channel 5 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
29/30
Calibration resistance, channel 6 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
31/32
Calibration resistance, channel 7 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
33/34
Initial calibration resistance, channel 0 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
35/36
Initial calibration resistance, channel 1 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
37/38
Initial calibration resistance, channel 2 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
39/40
Initial calibration resistance, channel 3 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
41/42
Initial calibration resistance, channel 4 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
43/44
Initial calibration resistance, channel 5 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
45/46
Initial calibration resistance, channel 6 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
47/48
Initial calibration resistance, channel 7 (in 0.1 m
Ω)
0
0…6553.5 m
Ω
!