Device functions
Version 2
UPT-6010
Seite 23
device master files and the associated image files (.BMP) for visualization in the configuring tool can be requested
by e-mail (
) or downloaded from our website (
If the controller already has an IP address, the device master file can also be downloaded from the integrated web
server.
After linking the required device master file into the configuring tool, you must assign a unique name to the con-
troller (device initialization). The controller is shipped without a name. You must also select the desired parameter
values.
8.4
Communication protocol
The communication protocol consists of 2x16 bit input words and 3x16 bit output words (from the point of view of
the controller). This protocol separates the set point and the actual value of the UPT-6010 from the status infor-
mation and the control functions, to simplify decoding by the PROFINET controller.
Bits 0…7 form the low byte and bits 8…15 the high byte ("INTEL format").
The 2 x 16 bit
input data
contains the set point in word
and the control functions in word
:
The 3 x 16 bit
output data
contains the actual value in word
, the status information in word
, and the error
code in word
:
Spare
Set point / AC temperature
Name:
0
0
0
0
0
0
0
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Spare
Channel
Spare
Control function
Name:
0
0
0
0
0
CH2
CH1
CH0
0
0
0
MA
MP
RS
ST
AC
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Actual value (signed)
Name:
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Spare
Channel
Status information
Name:
0
0
0
MU
1
1. From firmware version 303
CH2
CH1
CH0
SA
IA
WA
AA
AG
AL
TE
TO
RA
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Error code
Name:
0
0
0
0
0
0
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0