84
5. Maintenance
5-4 Replacing the Consumable parts
Replacing the Wiper
If the screen shown in the figure appears, replace the wiper with a new one.
1
Follow steps 1 through 2 in "5-2 Cleaning Using the Cleaning Kit -- Before Starting Cleaning" to go to
the maintenance menu. Press the [ ] key to select [WIPER REPLACE], then press the [ENTER] key.
The printing carriage moves to a position above the platen.
2
Follow steps 6 and 7 in "5-2 Cleaning Using the Cleaning Kit -- Before Starting Cleaning" to detach the
right cover and discharge static electricity from your body.
3
Attach the stoppers at the locations shown in the figure.
Make sure the following screen appears.
For the stopper, use a cleaning stick or the like.
4
Press the [ENTER] key.
The wiper moves.
5
Using tweezers, grasp the bottom portion of the wiper and
take it off the hook.
6
Remove the wiper and install the new one.
Bottom portion
of the wiper
Hook
Felt
Wiper
Install in this groove.
The wiper has a rubber surface and a felt surface. Attach
the wiper so that the rubber surface faces the front.
Stopper
Rubber
TIME FOR
WIPER REPLACE
MAINTENANCE
WIPER REPLACE
INSERT STOPPER