100
6. About the Menus
Heater Configuration Menu
[PRINT/DRYER]
Setting range: OFF, 35 to 50ºC (in steps of 1º)
or 94 to 122ºF (in steps of 2º)
These specify the preset temperature for the printing heater and
for the dryer. They also display the actual temperatures. The value
on the left side of the display is the preset temperature, and the
value on the right side is the actual temperature.
Language/unit Menu
[MENU LANGUAGE]
Setting range: ENGLISH, JAPANESE
This specifies the language used for the display. After you have
made your selection, pressing the [ENTER] key displays the
[LENGTH UNIT] menu.
[LENGTH UNIT]
Setting range: mm, inch
This specifies the measurement unit for the lengths shown on the
display. After you have made your selection, pressing the [EN-
TER] key displays the [TEMP. UNIT] (temperature unit) menu.
[TEMP. UNIT]
Setting range: ºC, ºF
This specifies the measurement unit for temperatures shown on
the display. After you have made your selection, pressing the [EN-
TER] key exits the menus, and initialization starts.
Maintenance Menu
[MAINTENANCE] > [CLEANING]
This performs operations for cleaning around the printing heads
using the cleaning kit. For more information, go to "5-2 Cleaning
the Printing Heads" and refer to "Cleaning Using the Cleaning
Kit."
[MAINTENANCE] > [WIPER REPLACE]
This performs operations for replacing the wiper. For more infor-
mation, go to "5-2 Cleaning the Printing Heads" and refer to "Re-
placing the Wiper."
Preset temperature
6-2 Detailed Descriptions of the Menus
35 25
DRYER
35 25
Actual
temperature