26
TONE - VCA
(Voltage Controlled Amplifier)
VCA LFO Modulation Depth
D-5
Range 0-127
VCA LFO Source
D-6
1 = LFO 1, 2 = LFO 2
VCA Level
D-7
Range 0-127
VCA Mode
D-8
1 = Gate, 2 = Env 1, 3 = Env 2
TONE - LFO
(Low Frequency Oscillator)
LFO 1 & 2 Wave
Sine, Triangle, Saw, Rev Saw
Square, Random
LFO 2 - Seq Clocked Random
A-11
LFO 1
A-14
LFO 2
1 = Sine
2 = Triangle
3 = Saw
4 = Rev Saw
5 = Square
6 = Random
7 = Seq Clocked Random (LFO 2 Only)
LFO 1 & 2 Rate
A-12
LFO 1
A-15
LFO 2
Range 0-127 (0=slowest)
LFO 1 & 2 Delay
A-13
LFO 1
A-16
LFO 2
Range 0-127 (0=no delay)
LFO 1 & 2 Mode
B-11
1 = LFO 1 & 2 Normal (above and below base note)
2 = LFO 1 & 2 Plus (above base note only)
TONE - ENV 1 & 2
(Envelope Generators)
Envelope 1 & 2 Attack
C-13
ENV 1
D-13
ENV 2
Range 0-127
Envelope 1 & 2 Decay
C-14
ENV 1
D-14
ENV 2
Range 0-127
Envelope 1 & 2 Sustain
C-15
ENV 1
D-15
ENV 2
Range 0-127
Envelope 1 & 2 Release
C-16
ENV 1
D-16
ENV 2
Range 0-127
Envelope 1& 2 Speed
D-12
ENV 1/2
1 = Normal Speed, 2 = Half Speed
TONE - Chorus
Chorus Off/Auto/Manual (with upgrade
fitted)
D-3
1 = Off, 2 = Auto, 3 = Manual
Chorus Rate (with fitted)
D-4
Range 0-127
www.kiwitechnics.com
3P Upgrade User Manual v400
Summary of Contents for JX-3P
Page 1: ......
Page 4: ...4 Control Description www kiwitechnics com 3P Upgrade User Manual v400...
Page 5: ...5 Basic Connections www kiwitechnics com 3P Upgrade User Manual v400...
Page 7: ...7 Software Flow Chart www kiwitechnics com 3P Upgrade User Manual v400...
Page 8: ...Menu Flow Chart...
Page 24: ...24 Edit Parameters www kiwitechnics com 3P Upgrade User Manual v400...