Filling Draw back
This parameter allows
to enable or disable
the yarn filling draw back after yarn cut. It is also
possible to choose how large angle to use to pull the yarn back.
• Possible setting:
off
disabled filling draw back
1
minimum angle for draw back
2
middle angle for draw back
3
maximum angle for draw back
• Recommended setting: Use mostly "
2"
and "
3"
values .
Sensors sensitivity settings
Reaction time of the Feed Sensor
Set the sensitivity for the photocell with function as input yarn break sensor
• Possible setting: 2, 3, 4, 5 and OFF (OFF = Feed Sensor OFF)
• Recommended setting: 3
Note:
increase the value in case of “false” yarn break stops
Winding sensor
Sets the sensitivity of the photocell which is controlling the outgoing coils.
• Possible setting: normal yarn / fine yarn
• Recommended setting: normal yarn
Reserve sensor
Sets the sensitivity of the photocell which is controlling Automatic Reserve Position.
• Possible setting: normal yarn / fine yarn