92 / 341 - EN -
12.2.
Changing parameters
Step
Display
Description
Remark
1
Switching the control unit off
2
ROHDE
Press the
j
and
<
keys and switch on
the control system at the same time.
With older ST 630 controllers, you only
have to press the
j
key and switch on the
control system at the same time.
3
tC. S
Hold down the
j
and
<
keys until the
set thermocouple type is shown in the
main display.
⇒
The thermocouple type is only
displayed and cannot be changed here.
⇒
The thermocouple is preconfigured at
the factory.
4
tC. S
Release the
j
and
<
keys.
5
P14-
The main display shows the first
configurable parameter.
6
P45-
The parameter to be configured can be
selected by pressing the
d
and
f
keys.
7
0
The set value of the parameter to be
configured can be called up with the
g
key.
You can return to the previous menu at any
time with the
h
key.
8
3
This can be altered by pressing the
d
and
f
keys.
9
3
The value is saved by pressing the
j
and
<
keys at the same time.
As an example, the value from “0” to “3”
was set here for parameter no. 45 for the
additional switch output 1
(3 = control of a cooling system using a fan
on the kiln).
10
The control system display goes dark for
a moment and the control system
restarts.
11
After the restart, the control unit is ready
for operation again.
The set value is now permanently saved for
the respective parameter.
12
P:45
Alternatively, after step 8, press the
h
key to jump back to the previous menu or
to change another parameter.
Repeat steps 6 to 12.
Note:
If no button is pressed for 30 seconds, the control automatically exits the configuration menu.
„TIMEOUT!“
is shown
in the main display and a short beep sounds for 3 seconds. Previous entries are not saved and will be lost.
Summary of Contents for ST 630
Page 344: ...20220531 01 ...