71 / 341 - EN -
7.4.
Program switch outputs (ST 632 only)
7.4.1.
Event programming (ST 632 only)
To be able to program an event in the firing program, the additional switch output must first be set to “1” in the
parameter configuration (see Section 12. / Parameter no. 45 or 49).
Programming procedure:
When programming a ramp or a soak period – while programming a firing program – the switch output can also be
selected for the respective program step by pressing the switch output (event) key. Events are possible with a ramp as
well as a soak period.
Programming an event for a ramp:
Main display
Meaning
Switch output
indicator
Description
150°C/HR
Heating ramp
Cooling ramp
Event 1:
While programming a ramp, press the
<
key and then
the
g
key to select event 1.
Event 2:
While programming a ramp, press the
<
key and then
the
h
key to select event 2.
Event 1 & Event 2:
While programming a ramp, press the
<
key and then
the
g
key to select event 1 and then press the
<
key
and then the
h
key to select event 2.
Programming an event for a soak period:
Main display
Meaning
Switch output
indicator
Description
00 : 15
Soak time
Event 1:
While programming a soak time, press the
<
key and
then the
g
key to select event 1.
Event 2:
While programming a soak time, press the
<
key and
then the
h
key to select event 2.
Event 1 & Event 2:
While programming a soak time, press the
<
key and
then the
g
key to select event 1 and then press the
<
key and then the
h
key to select event 2.
Summary of Contents for ST 630