59
Remote Control
Internet later via a router, the private IP addresses used in
your local network can be maintained. Since within each
IP address range the first IP address is used as network
IP address and the last IP address is used as Broadcast IP
address, in each case two IP addresses have to be taken
off from the “number of possible host addresses“ (see
table 10.1: Private IP address ranges). Apart from the or-
ganization of IP addresses into public and private address
ranges, IP addresses are also divided into classes (Class:
A, B, C, D, E). Within the classes A, B, and C are also in-
clude the private IP of address ranges described before.
The categorisation from IP addresses is for the assignment
of public IP address ranges of importance and essentially
depends on the size of a local network (maximum number
of hosts in the network), which is to be connected with the
Internet (see table 2: Classes of IP addresses). IP addresses
can fix (statically) or variable (dynamically) to be assigned.
If IP addresses in a network are assigned fix, an IP address
must be preset manually with each network element. If IP
addresses in a network are assigned to the attached net-
work elements automatically (dynamically), a DHCP server
(English DHCP becomes; Dynamic Host Configuration
Protocol) is required for the dispatching of IP addresses.
With a DHCP server an IP address range for the automatic
dispatching of IP addresses can be preset. A DHCP server
is usually already inte-grated in a router (DSL router, ISDN
router, Modem router, WLAN router, …) integrated. If a
network element (e.g. an instrument) is connected by a
network cable directly with a host (PC), the IP addresses
cannot be assigned to the instrument and the host (PC) au-
tomatically, since no network with DHCP server is present
here. They have to be preset therefore at the instrument
and at the host (PC) manually.
IP addresses are divided by using subnet mask into a
network quota and into a host quota, so similarly e.g. a
telephone number is divided in pre selection (land and local
area network number) and call number (user number).
Subnet mask have the same form as IP addresses. They
are represented with four decimal numbers separated
by points (e.g. 255.255.255.0). As is the case for the IP
addresses here each decimal number represents a binary
number of 8 bits. The separation between network quota
class
adress range
net quota
host quota max. number of networks max. number of hosts
A
0.0.0.1 - 127.255.255.255
8 Bit
24 Bit
126
16.777.214
B
128.0.0.1 - 191.255.255.255
16 Bit
16 Bit
16.384
65.534
C
192.0.0.1 - 223.255.255.255
24 Bit
8 Bit
2.097.151
254
D
224.0.0.1 - 239.255.255.255
Reserved for multicast applications
E
240.0.0.1 - 255.255.255.255
Reserved for special applications
Table 10.2: Classes of IP adresses
adress range
subnetz mask
CIDR way of writing
number of possible host adresses
10.0.0.0 –10.255.255.255
255.0.0.0
10.0.0.0/8
2
24
− 2 = 16.777.214
172.16.0.0 –172.31.255.255
255.240.0.0
172.16.0.0/12
2
20
− 2 = 1.048.574
192.168.0.0 –192.168.255.255
255.255.0.0
255.255.255.0
192.168.0.0/16
192.168.0.0/24
2
16
− 2 = 65.534
2
8
− 2 = 254
Table 10.1: Private IP adress ranges
and host quota is determined by the subnet mask within
an IP address (e.g. the IP address 192.168.10.10 by the
subnet mask 255.255.255.0 is divided into a network quota
192.168.10.0 and a host quota of 0.0.0.10). The allocation
takes place via the transformation of the IP address and
the subnet mask in binary form and afterwards a bit by bit
one logical AND operation between IP address and subnet
mask. The result is the network quota of the IP address.
The host quota of the IP address takes place via the bit by
bit logical NAND operation between IP address and subnet
mask. By the variable allocation of IP addresses in network
quota and host quota via subnet masks, one can specify IP
address ranges individually for large and small networks.
Thus one can operate large and small IP networks and
connect if necessary to the Internet via a router. In smaller
local networks the subnet mask 255.255.255.0 is mostly
used. Network quota (the first 3 numbers) and host quota
(the last number) are simple here without much mathe-
matical expenditure to determine and it can with these
subnet mask up to 254 network elements (e.g. measuring
instruments, hosts/PC‘s...) in a network be operated at the
same time.
Often also a standard gateway is present in a network. In
most local networks is this gateway with the router to the
Internet (DSL router, ISDN router etc.) is identical. Using
this (gateway -) router a connection can be manufactured
with another network. Thus also network elements, which
are not in the same (local) network, can be reached and/
or network elements from the local network are able to ex-
change data with network elements from other networks.
For a network-spreading data exchange the IP address of
the standard gateway must also be preset. In local net-
works, mostly the first IP address within a network for this
(gateway -) router is used. Mostly routers in a local network
to be used as gateway have an IP address with a „1“ in the
last place of the IP address (e.g. 192.168.10.1).
9.3.2 Ethernet settings
In addition to the USB interface, the interface card includes
an Ethernet interface. Select Ethernet as interface and
press the soft menu key PARAMETER to then determine
the settings for the necessary parameters directly within
Summary of Contents for HMC8012
Page 34: ...34 Anhang ...
Page 66: ...66 Appendix ...
Page 67: ...67 Appendix ...
Page 68: ...68 Appendix ...