Security Locks SL2000F and SL2000F-VP EN 

 

2020-05-06 

 

Page 

2

 of 

12

 

 

 

Features 

 

Door Lock

 output to control door locking device   

 

Status

 output to signal current working mode: Armed or Disarmed 

 

Alarm

 output to indicate Door Bell and Door Alarm 

 

Door Contact

 input for detection of door status 

 

Exit Button

 input to unlock the door from the external button  

 

INSTALLER code for programming  

 

MASTER code switch between armed and disarmed modes 

 

USER codes for door unlocking 

 

Programmable length of codes 

 

User indexing for easy administration of the codes 

 

Nonvolatile memory 

 

Plastic enclosure and keypad with backlight, indoor operation (SL2000F) 

 

Metal, silver color case and keypad, outdoor operation (SL2000F-VP) 

 

Three LEDs and buzzer 

 

Tamper 

 

12VDC supply 

 

CE 

Introduction 

The SL2000F electronic code lock is dedicated to operate as a standalone door access control unit. It is 
equipped with one relay output, two transistor outputs and three inputs. All codes and parameters programmed 

to device are stored in nonvolatile memory.  
There are two version of SL2000F lock: 

 

SL2000F (plastic enclosure, indoor operation only) 

 

SL2000F-VP (metal front cover and keys, outdoor operation available) 

Both lock’s version have the identical functionality, differences are limited to the mechanical construction only. 

Functional Description 

REL1 and OUT1 Outputs 

 

Note: The C1,C2…C10 parameters which appear in this manual refer to the configuration parameters 
programmed to the SL2000 during Memory Reset procedure (for details see section: 

Configuring the SL2000

 

later in this document).  

Summary of Contents for SL2000F

Page 1: ...Electronic Code Lock SL2000F and SL2000F VP v2 0 Rev F ...

Page 2: ...oor operation SL2000F VP Three LEDs and buzzer Tamper 12VDC supply CE Introduction The SL2000F electronic code lock is dedicated to operate as a standalone door access control unit It is equipped with one relay output two transistor outputs and three inputs All codes and parameters programmed to device are stored in nonvolatile memory There are two version of SL2000F lock SL2000F plastic enclosure...

Page 3: ...n be used to control arming mode of the alarm zone or entire alarm system When the SL2000 is in Armed mode this output remains not active it become active when lock works in Disarmed mode The Status Output can be physically assigned to either Relay or OUT1 physical output for details see JP2 JP3 JP4 and JP5 settings The Status output can be used for rearming of an alarm zone or to control any othe...

Page 4: ... re enable access to the controlled door by switching the lock to the Disarmed mode The SL2000 can be switched between Armed and Disarmed modes via the MASTER code only Arming and Disarming In normal operation the SL2000 may work either in the Armed or Disarmed mode The actual status of the lock is presented on a dual color LED STATUS which lights up in red when lock is Armed and green when Disarm...

Page 5: ...ries of two beeps Normally pressing is used to mark the end of the code but when pressed separately for a time longer the 0 5s it triggers Door Bell indication Programming The USER Codes The SL2000 enables programming of up to 55 different USER codes The USER codes can be managed added deleted changed only in the Installer Programming mode to enter Installer Programming mode press INSTALLER Code O...

Page 6: ...from 00 to 99s default 04 C3C4 Specifies the time for which Door Lock output will be activated It can be programmed from 02 to 99s default 04 C5C6 Specifies the time within door must be closed otherwise Door Alarm will occur The C5C6 time is started from the moment when C4C4 time has passed by It can be programmed from 00 to 99s the 00 value sets unlimited time for door closing default 09 C7 Enabl...

Page 7: ... door 33 seconds Reprogramming of the MASTER code disabled Reprogramming of the INSTALLER code enabled Option 1 Timed Lock out off Option 2 Disable USER Codes When in Armed Mode off USER codes length 6 digits MASTER and INSTALLER codes length 10 digits Default Codes After the Memory Reset is accomplished Sl2000 restores following codes MASTER Code All digits are 1 1111 the length of the code depen...

Page 8: ... lock must be supplied form reliable power source calculate the adequate wire gauge to guarantee that the voltage on the SL2000 DC input will be 11 5V minimum Use separate pair of wires to supply door lock and SL2000 code lock Always add the silicon diode e g 1N4007 in parallel to the door lock note that diode must be located as close as possible to the door lock terminals It is forbidden to suppl...

Page 9: ...Security Locks SL2000F and SL2000F VP EN 2020 05 06 Page 9 of 12 ...

Page 10: ...Security Locks SL2000F and SL2000F VP EN 2020 05 06 Page 10 of 12 ...

Page 11: ...tion 12V 1 Red Supply input plus GND 2 Black Supply input minus TMP A 3 Grey Tamper contact A NC max 50mA 24V DC AC TMP B 4 Yellow Tamper contact B NC max 50mA 24V DC AC IN1 5 Blue Exit Button input NO type IN2 6 Red Blue Door Contact input NO type 1 5A 24V DC AC SYS 7 Pink LED SYSTEM input NO type OUT1 8 Green Transistor output max current sink 50mA 15V DC OUT2 9 Brown Transistor output max curre...

Page 12: ...ztum Gosciszewo 59 Tel 48 55 272 01 32 Fax 48 55 272 01 33 Technical support PSTN 48 55 267 01 26 e mail biuro roger pl Web www roger pl The symbol of a crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labelled as such must not be disposed of with norma...

Reviews: