This is a read-only parameter that displays the value of the DC Bus Volts. This value changes as the DC Bus Volts varies,
and you can see that here. Click Cancel.
Scroll down even further to Parameter 535 [Accel Time 1], and then double-click on this parameter to view and edit it
This is a writeable parameter that determines the acceleration rate it takes to go from 0 Hz to Parameter 27 [Motor NP
Hertz] or Parameter 28 [Motor NP RPM], according to the setting in Parameter 300 [Speed Units]. To edit this parameter, a
new value would be entered, followed by clicking OK. In this case though, click Cancel.
Similar to PowerFlex 525, the PowerFlex 755’s Add-On Profile has a time saving feature with Connected Components
Workbench software that will show the non-default parameters. This makes it easy for users to view which parameters
were changed from their default setting.
This button only updates the set of parameters shown based on the upload. When a parameter changes
from defaults after clicking the button, it won't be added to the list until the view is refreshed.