52 of 136
63.
Select ‘3 wire’ as your choice for the question ‘Enter Choice for the control method’.
64.
In the ‘Select Port To Use’ window use the up and down arrow keys to highlight ‘Port 07 I/O Module 24V’ Press the
‘ENTER’ soft key to make this your selection.
65.
In the ‘Param to Use’ window Press the Enter soft key to select
66.
First, you will select the bit/Digital Input you want to use as your START. We are going to use the green push button
labeled ‘IN 1’ as our start input. To do this scroll to Bit 01 Input 1 and press the Enter soft key.
67.
Repeat steps 66 and 68 to select the red push button labeled ‘IN 0’ as your Stop switch (Bit 00 Input 0) and the
selector switch labeled ‘IN 2’ as your Forward/Reverse switch (Bit 02 Input 2) in that order.
68.
Back in the ‘Start Stop I/O’ menu screen. Scroll down to ‘Analog Outputs’ and select ‘ENTER’.
69.
In the ‘Select Port To Use’ window use the up and down arrow keys to highlight ‘Port 07 I/O Module 24V’ Press the
‘ENTER’ soft key to make this your selection.
70.
Select the ‘Anlg In0 Value’.
71.
In the next page that comes up, select ‘Voltage’ for Analog Out 0 type.
72.
Set the ‘Anlg Out0 DataHi’ to 10.0 volts and set the ‘Anlg Out0 DataLo’ to 0.0 volts.
73.
Repeat for ‘Anlg Out0 Hi’ and ‘Anlg Out0 Lo’.
74.
Press the ‘ENTER’ soft key to select ‘Disabled’ for the ‘Anlg Out1 Sel’.
75.
You should now be back in the ‘Start Stop I/O’ menu screen. This is all we will configure in this section so use the
down arrow keys to scroll down to the last item on the list ‘Done’. After ‘Done’ is highlighted, use the ‘ENTER’
soft key to make this your selection.
76.
You should now be back in the General Startup Main Menu screen .you have finished with the Startup routine steps
required for this lab session. Select ‘Done’ using the ‘ENTER’ soft key to exit out this screen.
77.
Select ‘Exit Startup’ using the ‘ENTER’ soft key to exit out of the Startup routine.
78.
You can now test your drive to perform the functions you configured during the startup routine namely, Start using the
green push button IN 1, Stop using the red push button IN 0, change direction using IN 2 and provide speed reference
using the ‘0-10VDC IN 0’ pot.
Summary of Contents for PowerFlex 525
Page 8: ...8 of 136 About the PowerFlex 525 Demo Box ...
Page 9: ...9 of 136 About the PowerFlex 755 DHQ Demo Box ...
Page 12: ...12 of 136 Control and Navigation Keys ...
Page 34: ...34 of 136 Relay Outputs changes required Opto Outputs Analog Outputs ...
Page 126: ...126 of 136 Default Machine States Default Machine Commands ...
Page 129: ...129 of 136 DMAT Device Status Rungs ...
Page 130: ...130 of 136 DMAT Application Status Rungs ...
Page 132: ...132 of 136 ...