44 of 136
Edit Motor NP Volts
230.00 VAC
0.10
264.50
Startup
Motor Data Entry
Def
Min
Max
230.00
EXP
18.
The next information you need to provide is the Power Units. By default the value of the parameter should be set to
‘HP’. Press the ‘ENTER’ soft key to confirm your selection and move to the next screen.
ABORT
ENTER
Startup
HP
kW
Motor Data Entry
Select type of power units
Shown on motor nameplate:
19.
You will now be required to input the Motor Nameplate (NP) Power. The motor internal to the demo is rated 25 Watts
(0.025 kW) or 0.033 HP. Notice that there are no designated buttons on the HIM keypad for entering a decimal point.
The PowerFlex 755 HIM keypad uses a soft key to provide a ‘decimal point’ button. This ‘decimal point’ soft key is
activated when the first digit in the numeric value is entered. In this case, start by entering ‘0’. Notice how one of the
soft keys (top row of the HIM keypad) is now a ‘decimal point’ button. Use the ‘decimal point’ soft key button and the
appropriate number keys to input a value of ‘0.033’. Press the ‘ENTER’ soft key to confirm your input and move to the
next screen.