![Rockwell Automation Allen-Bradley PanelView Plus 400 User Manual Download Page 110](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-panelview-plus-400/allen-bradley-panelview-plus-400_user-manual_1475651110.webp)
Publication 2711P-UM001D-EN-P - September 2005
5-10
Install and Replace Components
Replace the Display
Module
This section shows how to replace the display module. It is necessary
to remove the communication module from the logic module to
perform this operation.
1.
Disconnect power from the terminal.
2.
Remove the terminal from the panel.
3.
Detach the communication module (if attached) from the logic
module by removing the four screws.
4.
Loosen the six captive screws that attach the logic module to the
display module.
5.
Carefully lift the logic module from the terminal.
6.
Set the display module aside.
700 - 1500 Terminals Only
Communication Module
Display
Module
Logic Module
Logic Module
Captive screws
on top and bottom
Summary of Contents for Allen-Bradley PanelView Plus 400
Page 1: ...PanelView Plus Terminals 2711P 400 600 700 1000 1250 1500 User Manual...
Page 6: ...Publication 2711P UM001D EN P September 2005 Table of Contents iv...
Page 44: ...Publication 2711P UM001D EN P September 2005 2 16 Installation...
Page 56: ...Publication 2711P UM001D EN P September 2005 3 12 Connect Power...
Page 160: ...Publication 2711P UM001D EN P September 2005 7 12 Transfer files and Upgrade Firmware...
Page 176: ...Publication 2711P UM001D EN P September 2005 8 16 Troubleshooting...
Page 182: ...Publication 2711P UM001D EN P September 2005 B 2 Compatible USB Devices...
Page 191: ...Publication 2711P UM001D EN P September 2005 Index 5...
Page 192: ......