SECTION 4—PROGRAMMING
Program Setting
Valid Entry Range
Factory Default Setting
User Inputs 1 - 6
User Inputs 7 - 8
Brake Monitor
Counter
System Setup
Angle Settings
Timed Settings
Optional Modes
Variable Speed Top-Stop
Settings
PLS Outputs 1 - 2
Auxiliary Output
Logic:
Off, N.O. (Normally Open),
or N.C. (Normally Closed)
Stop Type:
E-Stop or Top Stop
Message:
See list of User Messages
on page 40
Logic:
Off, N.O. (Normally Open),
or N.C. (Normally Closed)
Stop Type:
E-Stop or Top Stop
Message:
See list of User Messages
on page 42
Open Angle:
0 - 359°
Close Angle:
0 - 359°
Warning Setpoint:
0 - 999 ms
Fault Setpoint:
0 - 999 ms
STM Angle:
20° - 340°
Batch Preset:
0 - 9,999,999 strokes
Security Code:
User-programmed up to 4 numbers
Network Address:
0 - 32
Single Stroke
Top Stop:
90° - 359°
Continuous
Top Stop:
0° - 359°
Auto Up:
90° - 345°
Light Curtain Mute:
45° - 345°
Anti-Tie-Down:
100 - 7000 ms
Timed Inch:
0 - 999 ms
Signal Time-out:
1 - 120 seconds
Continuous-On-
Demand:
On or Off
Foot-Maintained
Continuous:
On or Off
Two-Hand-Maintained
Continuous:
On or Off
One-Hand/Foot Trip:
On or Off
Auto Single Stroke:
On or Off
Speed:
4 - 500 SPM
Angle:
0° - 359°
On Angle:
0° - 359°
Off Angle:
0° - 359°
Counter:
0 - 999 strokes
Timed Off:
0 - 999 ms
Aux Out Batch Count:
Off
Aux Out Fault:
Off
Aux Out Stop:
Off
Aux Out E-Stop:
Off
Aux Out Logic:
N.O. (Normally Open) or N.C.
(Normally Closed)
QUICK REFERENCE TABLE - FACTORY SETTINGS AND VALID RANGES Table 4.1
Logic:
Off
Stop Type:
E-Stop
Message:
Clutch/Brake
Air Fault
Logic:
Off
Stop Type:
E-Stop
Message:
Clutch/Brake
Air Fault
Open Angle:
0°
Close Angle:
0°
Warning Setpoint:
50 ms
Fault Setpoint:
50 ms
STM Angle:
90°
Batch Preset:
0 strokes
Security Code:
0
Network Address:
0
Single Stroke
Top Stop:
330°
Continuous
Top Stop:
330°
Auto Up:
180°
Light Curtain Mute:
170°
Anti-Tie-Down:
250 ms
Timed Inch:
0 ms (Off)
Signal Time-out:
5 seconds
Continuous-On-
Demand:
Off
Foot-Maintained
Continuous:
Off
Two-Hand-Maintained
Continuous:
Off
One-Hand/Foot Trip:
Off
Auto Single Stroke:
Off
Speed—Angle
Speed—Angle
20 SPM—330°
80 SPM—318°
40 SPM—326°
100 SPM—314°
60 SPM—322°
120 SPM—310°
On Angle:
0°
Off Angle:
0°
Counter:
0 strokes
Timed Off:
0 ms
Aux Out Batch Count:
Off
Aux Out Fault:
Off
Aux Out Stop:
Off
Aux Out E-Stop:
Off
Aux Out Logic:
N.O. (Normally
Open)