Rockford Systems, LLC.
Call: 1-800-922-7533
21
SSC-1500 Part Revolution Solid-State Control
SECTION 3—INSTALLATION OF COMPONENTS
Photo 3.16
Keypad/Display
KEYPAD/DISPLAY ASSEMBLY
The keypad/display assembly, Part No. FTL-047 (photo 3.16) is used to
enter setup information and to monitor machine operation.
The keypad/display can be furnished in a remote enclosure up to a
maximum of 150’ from the SSC-1500 control module. Information
displayed during the machine run cycle are
Angle, Speed, Batch
Counter, Total Counter, Mode,
and
Stop Time
. All programming is
accessed by a program OFF/ON keyed selector switch. See pages 39 -
66 of this manual for programming information.
Mounting the Control Box
Solidly mount the control box in an accessible location, either on or
near the machine to be controlled. A convenient location will keep
conduit runs to a minimum length.
Note: On OBI (open back inclinable) presses, caution must be used to
ensure that the control box location does not interfere with the
ability to incline the press to its maximum position. On inclined
presses, the length and flexibility of each individual conduit run
must be carefully planned.
Although operation of this control will not be adversely affected by normal
machine operation, excessive shock or vibration may require shock
mounting in specific applications, and some applications may require
remote mounting of the control box (off the press). Special stands or
mounting brackets may need to be fabricated to accomodate remote
mounting.
(Continued on next page.)