Rockford Systems, LLC.
Call: 1-800-922-7533
49
SSC-1500 Part Revolution Solid-State Control
SECTION 4—PROGRAMMING
COUNTERS
The SSC-1500 press control has a batch counter that can be used for die maintenance, quality control checks, or part bin exchanges. This counter
has a programmable preset that will signal the press to top stop when the preset is reached. The preset has a maximum of 9,999,999 strokes.
There is also a total Counter, which has security code protection.
HOW TO PROGRAM THE COUNTERS
Select the
ON
position of the program OFF/ON selector switch. One of
the MAIN PROGRAM SCREENS will be displayed.
On the MAIN PROGRAM SCREEN, use
↓
and
↑
on the keypad to scroll
through the program options. Press
ENTER
when the arrow symbol
(>) is next to COUNTERS. The COUNTERS PROGRAM SCREEN will be
displayed. See Figure 4.25.
To enter a Batch preset:
Use
↓
and
↑
on the keypad to scroll up and down. You will see the
BATCH PRESET SCREEN. See Figure 4.26.
After you have entered a preset, press
ENTER
to finish. This will bring
you back to the COUNTERS PROGRAM SCREEN.
To clear the Batch Counter:
Use
↓
and
↑
on the keypad to scroll up and down. Press
ENTER
when
the arrow symbol (>) is next to Batch Clear. You will see the CLEAR
BATCH SCREEN. See Figure 4.27.
Press
YES
to confirm and the counter will be cleared.
To clear the Total Counter:
Use
↓
and
↑
on the keypad to scroll up and down. Press
ENTER
when
the arrow symbol (>) is next to Total Clear. The Security Code Screen
will be displayed. See Figure 4.28. You will be prompted to enter the
security code.
Press
ESC
to stop and return to the COUNTERS PROGRAM SCREEN.
Press
BKSP
to backspace or press
CLR
to delete the entry and start
over. Press
ENTER
when finished. After the correct security code has
been entered, you will see the CLEAR TOTAL SCREEN.
See Figure 4.29.
Press
YES
to confirm and the counter will be cleared.
Press
ESC
when finished to return to the MAIN PROGRAM SCREEN.
Figure 4.25
Counters Program Screen
Total Clear
Batch Clear
> Batch Clear
Figure 4.26
Batch Preset Screen
PROGRAMMING:
Batch Preset
0_ Strokes
Figure 4.27
Clear Batch Screen
Clear BATCH Counter?
Press: YES or NO
Figure 4.28
Security Code Screen
ENTER SECURITY CODE
_ CODE
Figure 4.29
Clear Total Screen
Clear TOTAL Counter?
Press: YES or NO