ROBOVENT •
DFS SERIES OWNER’S MANUAL
36
SEVERITY
HOURS OF
MAX AMBIENT
ATMOSPHERIC
INTERVAL
OF SERVICE
OPERATION
TEMP
CONTAMINATION
MULTIPLIER
PER DAY
Standard
8
104 F (40 C)
Clean, little corrosion
1
Severe
16 +
122 F (50 C)
Moderate dirt, corrosion
0.5
Extreme
16 +
>122F (>50 C) (NOTE 1)
Severe dirt, abrasive dust, corrosion
0.1
Low Temp
-22 F (-30 C) (NOTE 2)
1
Note 1: Use high temp grease
Note 2: Use low temp grease
Service Types
NEMA (IEC) FRAME SIZE
MOTOR HP
3600 RPM
1800 RPM
1200 RPM
900 RPM
Up to 125 (132)
5 HP
5500 hours
12000 hours
18000 hours
22000 hours
254 to 286 (160-180)
25 HP-30 HP
3600 hours
9500 hours
15000 hours
18000 hours
324 to 365 (200-225)
40 HP-50 HP
2200 hours
7400 hours
12000 hours
15000 hours
404 to 5000 (280-315)
100 HP-125 HP
2200 hours
3500 hours
7400 hours
10500 hours
Note: For vertically mounted motors and roller bearings, divide the relubrication interval by 2.
Relubrication Time Interval
NEMA (IEC) FRAME SIZE
MOTOR HP
LARGEST BEARING
OD D MM
WIDTH B MM
VOLUME OF
IN SIZE CATEGORY
GREASE
Up to 215 (132)
5 HP-15 HP
6307
80
21
4.5 grams
254 to 286 (160 - 180)
25 HP-30 HP
6311
120
29
9 grams
324 to 365 (200 - 225)
40 HP
6313
140
33
12 grams
404 to 5000 (280 - 315)
100 HP-125 HP
NU322
240
50
31.5 grams
Relubrication Amounts
SECTION 1000
Motor Greasing Guide
Summary of Contents for FloorSaver Series
Page 2: ......
Page 29: ...ROBOVENT FUSION 4 5 SERIES OWNER S MANUAL 65 SECTION 1000 Motor Greasing Guide ...
Page 38: ...ROBOVENT DFS SERIES OWNER S MANUAL ...
Page 41: ...APPENDIX A ePad Electronic Programmable Controller Instruction Manual ...
Page 51: ...APPENDIX B General Wiring Diagram ...
Page 52: ...B 1 ROBOVENT DFS SERIES OWNER S MANUAL APPENDIX B General Wiring Diagram Single Blower ...
Page 53: ...ROBOVENT DFS SERIES OWNER S MANUAL B 2 APPENDIX B General Wiring Diagram Double Blower ...
Page 54: ......
Page 55: ...APPENDIX C Parts List ...
Page 58: ......
Page 59: ......