Baldor Motor Greasing Guidelines
Lubrication Procedure
***Lock off and tag out power at the disconnect before servicing***
*** Motor should be warm prior to greasing***
1.
Locate the grease inlet, clean the area, replace the pipe plug with a grease fitting.
2.
Remove grease drain plug.
3.
Add recommended amount of grease. Stop when new grease appears at shaft hole
in the endplate or grease outlet plug.
4.
Replace grease inlet plug and run the motor for 15 minutes.
5.
Replace the grease drain plug.
Correct Grease Gun Procedures
1.
Use hand-operated grease gun, not a pneumatic grease gun. Pump grease slowly,
taking 10 to 12 seconds to complete each stroke.
2.
Apply quantity of grease called for. Over-lubrication can be as damaging as under-
lubrication.
3.
Do not over-lubricate motors. Over-lubrication of a motor can seriously damage it by
forcing grease into motor windings. Over-lubrication of the extract motor can force
grease into the centrifugal switch causing it to malfunction.
Approved Grease
•
Shell Dolium R (factory installed)
•
Chevron SRI (standard service conditions)
•
Darmex 707 (high temp conditions)
•
Arrowshell 7 (low temp conditions)
SECTION 1000
Motor Greasing Guide
Summary of Contents for FloorSaver Series
Page 2: ......
Page 29: ...ROBOVENT FUSION 4 5 SERIES OWNER S MANUAL 65 SECTION 1000 Motor Greasing Guide ...
Page 38: ...ROBOVENT DFS SERIES OWNER S MANUAL ...
Page 41: ...APPENDIX A ePad Electronic Programmable Controller Instruction Manual ...
Page 51: ...APPENDIX B General Wiring Diagram ...
Page 52: ...B 1 ROBOVENT DFS SERIES OWNER S MANUAL APPENDIX B General Wiring Diagram Single Blower ...
Page 53: ...ROBOVENT DFS SERIES OWNER S MANUAL B 2 APPENDIX B General Wiring Diagram Double Blower ...
Page 54: ......
Page 55: ...APPENDIX C Parts List ...
Page 58: ......
Page 59: ......