ROBOVENT • DFS SERIES OWNER’S MANUAL
16
SECTION 500
Specifications
Model DFS-12000-12 FloorSaver Dust Collector
Standard Features:
PowerFlex™: Pulsing System to
deliver constant pulsing pressure
across entire filter
E-Pad™: Control Board - Touch
Screen Panel to control all system
Functions
SafeSensor™: Particulate
Monitoring Device
Heavy Duty Construction: Fully
welded 7-10 Gauge Steel
Nema 12 Super Seal Doors and
Control Panel Enclosure
Internal Slide-Out Dust Tray: For
Fast and Easy Removal of Accumu-
lated Particulate
Available Options:
E-Drive™: Automatically adjust
the Airflow via a Flow Monitor
and VFD to extend Filter Life and
Reduce Energy Cost by up to 30%.
AutoSaver™: Auto On/Off Feature.
Supprex-200™: A Proprietary
Engineered Fire Suppression
System designed specifically for
Collector systems.
HEPA After Filters
Acoustical Sound Plenum:
Reduces Sound Levels up to 50%
.
E-Pad™ XE: Premium Controls
Upgrade
Model DFS-12000-12
Filter Media:
Comparable to 4,260 square feet
Filter Cartridges:
(12) EX-14D36-A13, Blended Non-Woven Media
Nanofiber
Electrical Requirements:
480 Volt, 3 phase, 17.5 amps, 17.5 amps,
23.5 amps, 36.0 amps**
Built-in Spark Arrestance:
(6) Metal Mesh (Part#: MM-17402)
(6) Spark Arrestance Baffles (Part#: FB-17402)
Pulse Valves:
(2) 1.5", Electronically Actuated Solenoids
Compressed Air Requirements:
2.6 SCFM On-Line Pulse; 15.6 SCFM Off-Line Pulse @ 80 PSI
Silencing:
Built-in Acoustical Lining
Weight:
3,990-4,120 Lbs. (depends on options) without Stand
Dimensions:
124" W x 60" D x 60" H
ePad Controls:
Included
Inlet
Clean Air Exhaust
Filter Access Door
Motor Enclosure Door
Electrical Enclosure
60”
60”
124”
DFS-12000-12 shown with
RVH Hood
DFS-12000-12-15-M1870 15 HP/18” @ 70% 6200 @ 5” 1.5:1
DFS-12000-12-15-M1890 15 HP/18” @ 90% 7950 @ 5” 1.9:1
DFS-12000-12-30-M18100 20 HP/18” @ 100% 8900 @ 5” 2.1:1
DFS-12000-12-30-C2270-V 30 HP/22” @ 70% w/VFD 8700 @ 17” 2.0:1
Model Number
Configuration CFM IN W.C
Air to
Cloth Ratio
This system is covered by one or more of the following patents: #6,758,875;
#4,610,704 and other patents pending. Due to continued engineering, all
specifications are subject to change without notice. ©2014 RoboVent
888.ROBOVENT (888.762.6836)
Specifications
Rev.#1 7/21/11
Summary of Contents for FloorSaver Series
Page 2: ......
Page 29: ...ROBOVENT FUSION 4 5 SERIES OWNER S MANUAL 65 SECTION 1000 Motor Greasing Guide ...
Page 38: ...ROBOVENT DFS SERIES OWNER S MANUAL ...
Page 41: ...APPENDIX A ePad Electronic Programmable Controller Instruction Manual ...
Page 51: ...APPENDIX B General Wiring Diagram ...
Page 52: ...B 1 ROBOVENT DFS SERIES OWNER S MANUAL APPENDIX B General Wiring Diagram Single Blower ...
Page 53: ...ROBOVENT DFS SERIES OWNER S MANUAL B 2 APPENDIX B General Wiring Diagram Double Blower ...
Page 54: ......
Page 55: ...APPENDIX C Parts List ...
Page 58: ......
Page 59: ......