8
4.3 Rigging the fixture
Danger of fire !
When installing the device, make sure there is no highly inflammable
material (decoration articles, etc.) in between a distance of min. 1,0 m.
The SCAN 1200 XT can be installed in any position without altering its operation characteristics
Install a safety wire that can hold at least 10 times the weight of the fixture. Never use the carrying handles for
secondary attachment.
Make sure that the device is fixed properly! Ensure that the structure
to which you are attaching the projectors is secure.
For fixing the projectors use the hole provided in the bracket. The hole in the adjustable mounting bracket has a
diameter of 10 mm.
For overhead use, fit a safety chain or cord.
4.4 Connection to the mains
Verify the power supply settings before applying power!
Connect the scanner to the mains with the enclosed power plug.If you need to install other power plug on the
power cable,follow the identification table below.
The earth has to be connected!
The occupation of the connection-cables is as follows:
Cable (EU)
Cable (US)
Pin
International
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green
Green
Earth
Do not connect the scanner to a dimmer system!
Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency.
The wrong settings can cause poor performance or demage of the moving head.The factory settings are printed
on the front panel of the scanner.
If you want to change the power supply settings,follow the instructions:
1.Disconect the scanner from AC power.Remove the small voltage/frequency selection panel on the front scanner
panel by loosening the 2 screws.
2.Move the wires on the transformer/ballast connection block to the desired position:
Transformer terminals
Ballast terminals