7
4. Installation
4.1Fitting the lamp
DANGER !
Install the lamps with the device switched off only.
Unplug from mains before !
To insert the lamp (Osram HMI 1200W) open the cover by loosening the fastening screws at the sides of the
cover.
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed for.
Damages caused by non-observance are not subject to warranty.
Insert the lamp now. Do not touch the glass-bulb with bare hands during the installation! Please follow the lamp
manufacturer‘s notes!
Before you close the cover again, make sure that the lamp is installed tightly into the lampholder system.
Reclose the housing and tighten the fastening screws.
Before striking the lamp, reset the "LAti"and "LASt" counters in the "INFO" menu of the control board, by
pressing the "Up" and "Down" buttons at the same time and then confirming with the "Enter"-button.
Do not operate this fixture with opened housing-cover!
4.2 Inserting/Exchanging rotating gobos
DANGER!
Install the gobos with the device switched off only.
Unplug from mains before!
Open the cover by loosening the fastening screws at the sides of the cover.
If you wish to use other forms and patterns as the standard-gobos, or if the gobos are to be exchanged, remove
the fixation-ring with an appropriate tool. Remove the gobo and insert the new gobo. Press the fixation-ring
together and insert it in the front of the gobo.
CAUTION!
Never unscrew the screws of the rotating gobo
as the ball bearing will otherwise be opened!