22
The fan automatically raises its speed in order to control inside temperature of the lighting, if the
temperature inside increases about certain level (the low fan speed reduces the cooling of the
lighting). This cycle can repeat several times until the temperature inside is on suitable level.The
initial level of the fan speed can´t be adjusted by the DMX.
High (max.) speed of fans
The cooling fan works on max. speed (max. cooling)
Continuous controlling of the fan speed
This mode is similar to "Auto", but the initial level of the fan speed can be adjusted by the DMX.
Low speed/Switch Off the lamp operating
The fan keeps the adjusted low speed until the temperature exceeds max. inside temperature of the
fixture, then the SCAN 1200 XT automatically switches off the lamp.
Low/high speed of the fan operating
The fan keeps the adjusted low speed until the temperature exceeds max. inside temperature of the
fixture, then the SCAN 1200 XT automatically switches from low to high the fan speed.
Note:The modes "Auto" and "HIGH" don´t interact to the DMX value on the channel 6 (0-127)!
Default settings
Press [Enter] to reset all fixture personalities (not the adjusting functions) to the default values. On the display
will appear "rSt" meaning that the fixture makes the reset. See the table of personality setting and their default
positions.
Personality
Display
Default values
(SHADED)
Display intensity
Display- reverse
Fan speed operating
modes
Switch On/Off
the lamp light sensor
Pan reverse
Tilt reverse
Movement resolution
Lamp On after switch.
the fixture On
Display-On
Lamp Off if DMX
is missing
Lamp Off via DMX
Lamp On if DMX
is present