3.2 Changing the lamp
DANGER !
Install the lamp with the fixture unplug from mains !
1. Disconnect the fixture from mains and allow it to cool approximately 60 minutes. Lock the head in a suitable
position (by means of the pan and tilt locks).
2. Unscrew the four hex socket head screws (1) (with washers and spring washers) on the lamp cover using
an Alen key 2.5 and remove the lamp cover (2).
3. Gently remove both fastons (3) from flat terminals of the lamp.
4. Holding the lamp by its ceramic base (4), carefully turn the lamp counter-clockwise by a quarter turn to release
the lamp from a lamp holder.
5 Holding the new lamp by its ceramics base (4), carefully insert the lamp into the lamp holder and turn it clockwise
by a quarter turn until you it reach a stop. Do not touch the lamp with bare hands. If necessary,
lamp can be cleaned with lint free towel before operation.
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is
not de signed for. Please follow the lamp manufacturer‘s notes.
6. Slide both fastons (3) on the lamp terminals and check that fastons are fastened properly.
7. Carefully check the gasket (5) for signs of deformities or hardening and if it is correctly placed in the groove of
the head housing.
8
. Re-insert the lamp cover (2) and tighten the four hex socket head screws
(1) using a tightening torque of 2-2.3Nm.
9. Connect the fixture to the mains.
10. Reset the "Lamp On Time” and "Lamp Strikes” counters in the menu "Information”.
This lamp emits ultra violet (UV) radiation and operates at high pressure!
Do not operate this fixture without properly fastened the lamp cover !
Unlocking and removing the lamp
Lamp in locked position
Turn the lamp left
Lamp in unlocked position
Screws(1) must be
tightened in
the order
1-->2-->3-->4
with a tightening
torque of 2-2.3Nm