3.6 Ethernet connection
To keep declared IP rating of the fixture, all used RJ45 and XLR connectors and cables have to meet
IP 65 rating.
The fixtures on a data link are connected to the Ethernet with ArtNet (or MANet, MANet2, sACN) communication
protocol. The control software running on your light console has to support some of the protocols.
ArtNet communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP.Its purpose is to allow
transfer of large amounts of DMX 512 data over a wide area using standard network technology.
IP address
is the Internet protocol address.The IP uniquely identifies any node (fixture) on a network.
The Universe
is a single DMX 512 frame of 512 channels.
The Robin iPointe65 is equipped with 8-pin RJ- 45 socket for Ethernet input.Use a network cable category 5
(with four “twisted” wire pairs) and standard RJ-45 plugs in order to connect the fixture to the network.
RJ-45 socket (front view):
RJ-45 plug (front view):
1- TD+
5- Not connected
2-
TD-
6-
RX-
3- RX+
7- Not connected
4- Not connected
8- Not connected
Patch cables that connect fixtures to the hubs or LAN sockets are wired 1:1,that is,pins with the same numbers
are connected together:
1-1 2-2 3-3 4-4 5-5 6-6 7-7 8-8
If only the fixture and the computer are to be interconnected,no hubs or other active components are needed.
A cross-cable has to be used:
1-3 2-6 3-1 4-8 5-7 6-2 7-5 8-4
If the fixture is connected with active Ethernet socket (e.g. switch) the network icon
will appear at the
bottom right corner of the screen:
Ethernet operation
Connect the Ethernet inputs of all fixtures with the Ethernet network.
Option “Artnet (gMaI or gMA2 or sACN)" has to be selected from “Ethernet Mode” menu on the fixture.
(DMX address=196)
(DMX address=40)
(DMX address=1)
IP addres=002.168.002.004
IP addres=002.168.002.003
IP addres=002.168.002.002
Universe=1
Universe=1
Universe=1
An advised PC setting: IP address: 002.xxx.xxx.xxx / 010.xxx.xxx.xxx (Different from fixture IP addresses)
NET mask: 255.0.0.0