Pattern I Rotation Error 1 (Pattern I Rotation Error 2 )
The messages will appear after the reset of the prism wheel 2 if some rotating prism not located in the default
position.
Pattern 2 Error 1 (Pattern 2 Error 2 )
The messages will appear after the reset of the prism wheel 2 if this wheel is not located in the default position.
Pattern 2 Rotation Error 1 (Pattern 2 Rotation Error 2 )
The messages will appear after the reset of the prism wheel 2 if some rotating prism is not located in the default
position.
Zoom Error 1 (Zoom Error 2 )
The messages will appear after the reset of the zoom module if the zoom lens is not located in the default position.
Focus Error 1 (Focus Error 2 )
The messages will appear after the reset of the focus module if the focus lens is not located in the default.
Gobo Carousel Error 1 (Gobo Carousel Error 2 )
The messages will appear after the reset of the rotating gobo wheel if the carousel of rotating gobos is not
located in the default position.
Gobo rotation Error 1 (Gobo Rotation Error 2 )
The messages will appear after the reset of the rotating gobo wheel if the rotating gobos are not located in the
default positions.
Static Gobo Error 1 (Static Gobo Wheel Error 2 )
The messages will appear after the reset of the static gobo wheel if this wheel is not located in the default position.
Effect wheel Error 1 (Effect wheel Error 2 )
The messages will appear after the reset of the effect wheel if this wheel is not located in the default position.
Internal Error
Communication error between PCBs (error or "noise" was detected on communication wires).
Pan/Tilt EMS Error
Control electronics cannot communicate with the EMS system.
Clean Air Filters
The message informs that the item "Elapsed Time" in the "Fixture Information" menu is at 0 value. Clean air
filters and reset this counter.
Lamp Fan 1 Error
The blower above lamp in the fixture head is faulty. The lamp has been switched off.
Lamp Fan 2 Error
The blower above lamp in the fixture head is faulty. The lamp has been switched off.
Gobo Fan Error
The small blower cooling gobo wheels is faulty. The lamp has been switched off.
Front Fan 1 Error
The blower in the front part of the head is faulty. The lamp has been switched off.
Front Fan 2 Error
The blower in the front part of the head is faulty. The lamp has been switched off.
Front Fan Error
One or two fans (Front Fan 3, Front Fan 4) in the front part of the head is faulty. The lamp has been switched off.