MICON 500C Electronic Sequencing
4
234AY00.INS R06
Computer Installation Guide
2.0
PRE-INSTALLATION CHECK (CONT’D)
4. Figure 3 (preceding page) indicates both counters (dollar and volume) are set to 0001. To
check the current configuration of your MICON 500C, use the INFO-PAC
receive
functions,
described in the
INFO-PAC m500C Programming Manual
, and outlined in steps a) to d)
below:
The
RX MICON
(m500) setting on the INFO-PAC is designed to receive MICON 500C
settings from units which have already been programmed.
To receive information from the MICON 500C:
a) Go to breaker box and turn power OFF.
Caution: Ensure breaker box does not feed
power to equipment which should remain ON.
The MICON 500C display should be flashing.
If display is blank, unit is in
sleep (i.e.,
battery save)
mode. To correct this, turn handle ON and OFF. Display will start
flashing.
b) Turn INFO-PAC m500C ON by pressing left arrow key. Using up or down arrow key,
scroll to INFO-PAC RX MICON option. Set
RX MICON on
by pressing left or right
pointing arrow key.
c) Take INFO-PAC and go to the front display of the MICON 500C electronic pumphead.
Locate optical sensor (oval “hole”) at right of price display on MICON 500C.
Aim INFO-PAC receiver / transmitter (located behind red tinted filter at centre edge of
INFO-PAC at MICON 500C optical sensor.
Red LED to left of MICON 500C price display flashes as INFO-PAC receives data from
MICON 500C.
INFO-PAC
MICON 500C
electronic
pumphead display
Aim top of
INFO-PAC
(red
window) at
optical
sensor
ON
FIGURE 4 – RECEIVING DATA FROM MICON 500C