MICON 500C Electronic Sequencing
18
234AY00.INS R06
Computer Installation Guide
FIGURE 14
DISPLAY DOLLAR AND VOLUME TOTALS
6.2
MICON 500C COMMUNICATOR OPERATION
The hand held communicator (part # MC 200D, available as an option) allows the reading of dollar and
volume totals and price setting, as described below. The communicator can also be used as a
troubleshooting tool to obtain current readings of product flow rate, temperature and pressure (see
section 6.2.3, page 20).
6.2.1 READING TOTALIZERS ON A SINGLE TIER DISPENSER
(SINGLE TIER: FOR TWO TIER TOTALIZER READING, GO TO PAGE 23.)
1. Ensure the dispenser handle is in the
OFF
position, and the 120 VAC (230 VAC European)
MICON head power is turned ON.
2. Aim the communicator’s transmitter (located on the top of the unit)
at the optical sensor located to the right of the price display.
3. Depress and hold the “SEL” key on the communicator. The red indicator to the left of the
price display will flash as the MICON 500C receives the communicator’s signal.
4. Hold the “SEL” key until the dollar sales total is displayed. Dollars sale total uses ten digits
of the dollars and volume displays preceded by the letters “d
l
”. Refer to Figure 14, below.
5. To display volume total, depress and hold the “SEL” key until the display shows “V
l
”
followed by the ten digit volume total. Pressing the “SEL” key repeatedly or holding it down
will cause the display to switch back and forth between volume and dollars totals.
TOTAL
DOLLAR SALES
DISPLAY
THIS DISPLAY READS:
$782564.93
TOTAL
UNIT SALES
DISPLAY
THIS DISPLAY READS:
96154.823 UNITS