MICON 500C Electronic Sequencing
16
234AY00.INS R06
Computer Installation Guide
FIGURE 13
PRICE SETTING
USING THE MICON
COMMUNICATOR
5.0
POST INSTALLATION CHECK
After completing the installation of the MICON and checking all wiring connections, correct operation
should be verified as follows:
1. Enter a price, as described below (also described in section 6.2.2 – Setting Prices, page
19).
a)
Go to breaker box and turn OFF AC power to MICON 500C electronic pumphead being serviced.
Caution: Ensure
breaker box does not feed power to equipment which should remain ON.
MICON display should be flashing.
If display is not flashing, unit is in
sleep
mode. To correct this, turn handle ON and OFF. Display will start flashing.
b)
Take the MICON hand held communicator and go to the front display of the MICON 500C electronic pumphead display.
c)
Aim the communicator at the optical sensor (oval hole ) at right of price display on MICON 500C.
d)
To set prices :
§
While aiming the communicator’s transmitter (located on the end of the unit) at the MICON 500C optical display
sensor, press and hold the “SET” until the display increments to the desired number.
§
Use the “SEL” key to select the next digit to be changed. Press and hold the “SET” key until the display increments
the desired number.
2. After entering a price, turn ON the 120 VAC (230 VAC European) MICON head power.
3. Place the dispenser handle in the OFF position. Turn ON dispenser sequencing power and
ensure that no product can be dispensed.
4.
If card lock equipment is being used
, place the dispenser handle in the ON position.
Authorize the MICON with the self serve equipment. This is normally done by inserting the
appropriate card into the card terminal, then entering data (i.e., i.d. number, mileage, etc.)
as required. The authorization signal received by the card terminal is sent to the MICON
500C head via input wire #14 (N. American) or #20 (European).
MICON hand held
communicator
MICON 500C
electronic
pumphead display
Aim end of
communicator
at optical
sensor