MICON 500C Electronic Sequencing
20
234AY00.INS R06
Computer Installation Guide
6.2.3 READING CURRENT PRODUCT FLOW RATE, TEMPERATURE AND PRESSURE
To obtain current product flow rate, ambient temperature, gas temperature and/or pressure transducer
readings:
1. Take the MICON hand held communicator and go to the front display of the MICON 500C
electronic pumphead.
2. Aim the communicator at the optical sensor (oval hole ) at right of price display on
MICON 500C.
3. To access current flow rate, temperature and pressure readings:
FLOW RATE READINGS
While aiming the communicator’s transmitter (located on the top of the unit) at the MICON
500C optical display sensor, press the “SET” key, and observe the MICON display. The
bottom of the MICON display should indicate “FLO”.
The middle display will indicate the
value of the flow rate, in fuel mass per minute.
The units of mass may differ if the
dispenser is equipped with a turbine meter. Units are determined by the calibration of the
meter output. For
Return to Normal Display
instructions, see next page.
AMBIENT TEMPERATURE
Follow steps 1 –3, top of this page. When the bottom MICON display indicates “FLO”,
press the “SET” key on the communicator a second time.
The bottom MICON display should now indicate “tA” (ambient temperature).
The middle
display will indicate the ambient temperature in Fahrenheit.
For
Return to Normal
Display
instructions, see next page.
GAS TEMPERATURE (tG)
Follow steps 1 –3, top of this page. When the bottom MICON display indicates “tA”, press
the “SET” key on the communicator again.
The bottom MICON display should now indicate “tG” (gas temperature).
The middle
display will indicate gas temperature in Fahrenheit.
For
Return to Normal Display
instructions, see next page.