SteelConnect SDI-5030 Gateway Hardware Installation Guide
27
Replacing disk drives
Replacing SteelConnect Gateway SDI-5030 Components
Removing and installing the air duct
The air duct is located on top of the fans. Lift the air duct straight up to remove it from the gateway. Align
the air duct over the fans and lower the air duct into place to reinstall the air duct.
Figure 3-5. Installing the air duct
Replacing disk drives
This section describes how to remove and replace the disk drives.
Note:
If you need to replace a gateway, you cannot move the disks to preserve your data. Each disk is encoded with
machine-level information and moving disks is not supported.
The SDI-5030 gateway is equipped with replaceable, hot-swappable, 3.5-inch hard-disk drives (HDD).
When replacing a drive, replace only one drive at a time. You must use approved disk drives. To order
disk drives, contact Riverbed Support at https://support.riverbed.com.
Note:
When you replace disk drives, you must wear a grounded ESD antistatic strap to protect the hardware against
electrostatic discharge. Make sure that the strap makes skin contact prior to handling equipment.
Caution:
Use caution when you remove or replace gateway components; they can become hot to the touch.
To replace a disk drive
1.
Remove the bezel.
See
“Removing and installing the bezel” on page 24
.