SteelConnect SDI-5030 Gateway Hardware Installation Guide
25
Removing and installing the chassis cover
Replacing SteelConnect Gateway SDI-5030 Components
3.
Lock the bezel, if needed.
Figure 3-2. Installing the bezel
Removing and installing the chassis cover
You need to remove the top cover to add or replace components inside the gateway. This section
describes how to work with the chassis cover.
The gateway must be operated with the gateway cover in place to ensure proper cooling.
Removing the chassis cover
1.
Power down the gateway and unplug all peripheral devices and the power cable.
2.
Remove the screw, if there is one, on the cover and loosen the two captive screws on the rear panel
of the cover.
Figure 3-3. Removing the cover
3.
Slide the cover back and lift upward.