RAVE
®
FAN
38
Pub. No. 54450034 Rev. 4 - © DECEMBER 2014
38
Pub. No. 54450034 Rev. 4 - © DECEMBER 2014
4. If the speed controller appears to be functioning properly, but the fan is not operating properly,
the VFD may not be receiving the proper signal. With a DMM, measure the voltage at each
corresponding VFD input:
I/O Check: Set fan to slowest speed (1 LED), Forward direction
If the proper voltage is present at the speed controller, but not at the VFD, a wiring error or
break in the cable is likely. Verify connections and test cable for continuity.
If the proper voltage is present at the VFD, but the VFD is not running at the commanded
speed (10 Hz, forward), a parameter setting may have been changed. Go to Step 6.
5. The speed controller uses three VFD inputs to select a preset speed. The actual speed value
(in Hz) corresponding to each preset speed is stored in the VFD parameters.
For example, when the speed controller displays six LEDs (Speed 6), it turns on input (Ll3).
When the VFD sees input Ll3 on, with inputs Ll2 and Ll4 off, it runs the fan at the speed stored
in parameter SP3 (52 Hz by default).
Rotational direction is determined by the Forward and Reverse signals. For the previous
example, the fan will run forward if VFD input Ll1 is on. If VFD input Ll5 is on, it will run in
reverse. If neither input is on, the fan will not operate.
Using a DMM, step through each of the seven speed settings and verify the proper input
states. Check for swapped wires if the input states do not match the following table.
TROUBLESHOOTING
Summary of Contents for Rave RHC 1234567-001
Page 3: ...RAVE FAN Pub No 54450034 Rev 4 DECEMBER 2014 3...
Page 4: ...RAVE FAN 4 Pub No 54450034 Rev 4 DECEMBER 2014 NOTES...
Page 10: ...RAVE FAN 10 Pub No 54450034 Rev 4 DECEMBER 2014 FAN DIMENSIONS Figure 2 Table 2 Table 3...
Page 22: ...RAVE FAN 22 Pub No 54450034 Rev 4 DECEMBER 2014 FAN CONTROL BOX LAYOUT...
Page 23: ...RAVE FAN Pub No 54450034 Rev 4 DECEMBER 2014 23...
Page 24: ...RAVE FAN 24 Pub No 54450034 Rev 4 DECEMBER 2014 FAN CONTROL BOX LAYOUT EMC OPTION...
Page 25: ...RAVE FAN Pub No 54450034 Rev 4 DECEMBER 2014 25...
Page 26: ...RAVE FAN 26 Pub No 54450034 Rev 4 DECEMBER 2014 FAN CONTROL BOX LAYOUT SINGLE PHASE...
Page 27: ...RAVE FAN Pub No 54450034 Rev 4 DECEMBER 2014 27...
Page 29: ...RAVE FAN Pub No 54450034 Rev 4 DECEMBER 2014 29 CONTROL BOX WIRING...
Page 30: ...RAVE FAN 30 Pub No 54450034 Rev 4 DECEMBER 2014...
Page 43: ...RAVE FAN Pub No 54450034 Rev 4 DECEMBER 2014 43 MOTOR TROUBLESHOOTING...
Page 44: ...RAVE FAN 44 Pub No 54450034 Rev 4 DECEMBER 2014 SCHNEIDER FAULT CODES TROUBLESHOOTING...
Page 45: ...RAVE FAN Pub No 54450034 Rev 4 DECEMBER 2014 45 ATV312 PARAMETER SHEET TROUBLESHOOTING...
Page 46: ...RAVE FAN 46 Pub No 54450034 Rev 4 DECEMBER 2014 ATV 12 PARAMETER SHEET TROUBLESHOOTING...