background image

Part No. F40BP74710001

Form No. BP7471-1

Revision: 131015

ETL Model No.: CF766

READ AND SAVE THESE INSTRUCTIONS

4

TH

AVENUE

6

60

0”

”  C

Ce

eiilliin

ng

g  F

Fa

an

n  O

Ow

wn

ne

err''s

s  M

Ma

an

nu

ua

all

Model Numbers

CF766BS00 -

Brushed Steel

with Chocolate Blades

CF766ORB00 - 

Oil Rubbed Bronze

with Oil Rubbed Bronze Blade

s

CF766SBS00 -

Brushed Steel

with Brushed Steel Blades

Net Weight: 

28.9

Lbs.

Questions, problems, missing parts: Before returning to the store call

Emerson Electric Customer Service 

8 a.m. - 6 p.m., Eastern, Monday-Friday

1-800-654-3545

www.emersonfans.com

CF766SW00 - 

Satin White

with Satin White Blades

CF766VS00 -

Vintage Steel

with Riverwash Blades

Summary of Contents for AVENUE CF766ORB

Page 1: ...shed Steel with Chocolate Blades CF766ORB00 Oil Rubbed Bronze with Oil Rubbed Bronze Blades CF766SBS00 Brushed Steel with Brushed Steel Blades Net Weight 28 9 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com CF766SW00 Satin White with Satin White Blades CF766VS00 Vintage St...

Page 2: ...l wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson ...

Page 3: ...eding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly M L H I J K N A B C D THIS SIDE UP THIS SIDE UP THIS SIDE UP E F G OFF ON PACKAGE CONTENTS 1 4 3 7 8 12 2 6 5 9 11 10 HARDWARE CONTENTS Part Description Quantity A Fan...

Page 4: ...Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for f...

Page 5: ...at this procedure for the remaining two blades assemblies 6 Remove the two setscrews from the top of the motor coupler Figure 3 Retain the setscrews for future use 7 Position the upper housing onto the upper housing plate aligning the two notched areas the six screw holes and the reverse switch hole Figure 3 U P THIS SIDE UP THIS SIDE UP UPPER HOUSING REVERSE SWITCH MOTOR COUPLER NOTCHED AREA 2 SE...

Page 6: ...is properly installed in the coupler cover then slide the coupler cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupler cover are both oriented correctly Figure 7 13 Reinstall the hanger ball Figure 7 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through th...

Page 7: ...wire connector of the motor connector Make sure the connector latches are closed properly 19 Carefully tuck all wires and splices into the light kit assembly NOTE Do not pinch wires between the lower housing and the switch adapter LOWER HOUSING LIGHT KIT ASSEMBLY LIGHT KIT ASSEMBLY SCREW 3 Figure 10 7 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF766 20 Remove...

Page 8: ...ersonal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 11 WAR...

Page 9: ...round wire 2 Refer to Figure 14 and 15 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiver white AC IN N wire c Securely c...

Page 10: ...g the three flat areas on the top edge of the glass with the three light kit tips on the light kit assembly and turn the glass bowl clockwise until it stops Figure 17 NOTE It is advisable to periodically check that the glass is seated fully clockwise in the light kit assembly Over lamping the fan will result in the light bulbs being automatically shut off Use only 60 watt maximum candelabra light ...

Page 11: ... Before starting disconnect power to the circuit at the fuse box or circuit breaker panel 7 Remove the faceplate and screws from the existing wall switch Pull switch out from wall outlet box 8 Disconnect wire from existing fan wall switch Figure 19 Setting Operating Frequency of Wall Control Your wall control has code switches which must be set in one of 32 possible code combinations The five leve...

Page 12: ...TO 120VAC SOURCE G R O UND OFF ON HIGH TO LOW BUTTONS ON OFF SWITCH O OFF ON LIGHT BUTTON FAN BUTTON POWER INDICATOR LIGHT OFF ON Figure 21 Figure 22 Operation of Your Reverse Switch IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the controls 17 Restore electrical power to the outlet box by turning the electricity on at the main fuse box...

Page 13: ...TL Model No CF766 Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install...

Page 14: ...m Solid State speed control variable speed controls If Solid State Control is used and motor noise results choose an alternative control method 5 Screws holding blades to flanges are loose 5 Tighten screws securely 3 Fan wobbles 1 Setscrews in motor coupler are not 1 Raise coupler cover and tighten setscrews securely excessively tightened securely 2 Setscrew in the hangerball downrod assembly is 2...

Page 15: ...Notes 15 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF766 ...

Page 16: ...16 ETL Model No CF766 12 Repair Parts 1 5 2 3 18 17 6 7 19 25 4 20 23 24 16 OFF ON 8 9 22 11 15 10 THIS SIDE UP 14 THIS SIDE UP 12 21 13 13 ...

Page 17: ... Stud 2 6 Lockwasher 2 7 Knurled Knob 2 8 Pin Clevis 9 Clip Hairpin 10 Screw Pan Head with Lockwasher 8 32 x 1 2 7 11 Screw Pan Head with Lockwasher 1 4 20 x 1 2 7 12 Screw Washer Head 10 32 x 1 4 10 13 Screw Pan Head 8 32 x 3 8 1 14 Nut Decorative 10 15 Upper Housing Plate 16 Blade Balance Kit 17 Ceiling Canopy 764348 BS 764348 ORB 764348 BS 764348 SW 764348 VS 18 Coupler Cover 764360 BS 764360 O...

Page 18: ...18 ETL Model No CF766 Notes ...

Page 19: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Page 20: ...Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74710001 Form No BP7471 1 Revision 131015 ETL Model No CF766 Printed in China 10 13 ...