14 - 3
CZ180 / CV1860 Rev. 1.0
CHAPTER 14: TEST MODE
No.
Sensors, switches
Detection status
0002
Solenoid counter connection
signal
Solenoid counter connected
0003 24V A output signal
24V-A ON (24V output)
0004 24V B output signal
24V-B ON (24V output)
0005 Rear cover safety SW
Switch ON (main unit rear cover is installed)
Other safety switches must be ON for this check.
No.
Unit check
0080
Test Print A (checkered)
Creates Test pattern 1 (Checker Flag)
0081
Test Print B (cross stripes)
Creates Test pattern 2 (Cross Lines)
0082
Test Print C (Dot1)
Creates Test pattern 3 (Dot 1 )
0083
Test Print D (Dot2)
Creates Test pattern 4 (Dot 2 )
0084
Test Print E (Dot 1 x Dot 1)
Creates Test pattern 5 (Dot 1 x Dot 1 )
0085
Test Print F (Dot 2 x Dot 2 )
Creates Test pattern 6 (Dot 2 x (Dot 2)
0086
Test Print 18% dots
Creates Test pattern B4 18% dots
0087
Paper-Feed Test (continuous feeding)
Prints continuously.
* The Speed key is enabled.
* If the rear cover safety switch is OFF, the operation begins when the rear cover safety switch is turned
ON within 10 seconds after the START key is turned ON.
0088
Low-Speed Printing Operation
Prints continuously at 15 rpm.
0090
Continuous master-making & printing
Continuous master-making & printing with test mode master-making without using original on the AF
unit.
* The printing quantity is set by Test Mode No. 0147.
* The test mode master-making type is selected by Test Mode No. 0148.
0094
Unit Initialization
Initializes the mechanical moving units to their home positions.
[ Scanner, thermal print head, compression plate, clamp units and
vertical print position.]
0095
System Configuration Data Output
Creates a master for the CI system data.
2. List of the Test Modes
1) System & Panel Test Modes
RISO Inc. Technical Services & Support
US.RISO.COM