Rinnai Australia
28
Sapphire Operation & Installation Manual
HEATER ENGINE - GENERAL INSTALLATION
ELECTRICAL SUPPLY
If a power point is used it
MUST BE
240 V, rated at 10A and
MUST BE
earthed.
This power point
MUST NOT
be located above the heater. Alternatively the
appliance can be direct wired if the power supply is to be concealed.
The heater engine is fitted with a 1.5 m power cord and three pin plug
which
exits the appliance from the rear panel at the lower left.
Direct Wired Installations
Alternatively the appliance can be direct wired if the power supply is to be
concealed.
Using Existing Externally Mounted Power Points on Inbuilt Installations
If you already have an existing wall plug located outside of the intended fireplace or enclosure you may redirect the
power cord and plug assembly through the front panel. With Fascia assembly removed, simply redirect the cord
and plug assembly with grommet from the rear of the unit, underneath the fire-box to the front of the unit, (either
left or right).
Carefully remove the pre-punched sheet metal 'knock-out' section located in the lower left or right edge
of the
Fascia Assembly. Refit the cord and plug assembly to the Fascia assembly ensuring the grommet is fitted to the
sheet metal. Excess cord may be left in the cavity below the fire box.
DO NOT
coil excess cord.
A qualified electrician will need to be consulted where a direct
wired installation is required. Any such installation must comply
with the requirements of AS 5601, AS 3000 and any other relevant
local regulations.
7a
7a
IMPORTANT
7
7
7