Rinnai Australia
25
Sapphire Operation & Installation Manual
HEATER LOCATION
GENERAL LOCATION INFORMATION
•
When positioning the heater, the main variables governing the location are Flueing and Warm Air Distribution.
•
This heater must not be installed where curtains or other combustible materials could come into contact with it.
In some cases curtains may need restraining. Refer to page 5 and page 6 for additional safety consideration.
•
Mantles and surrounds can be added to compliment the design provided that they conform to the clearances
shown in the diagrams below.
•
The minimum clearance from the edge of the appliance is 400 mm. The depth of the mantle/surrounds at the
minimum clearance may not exceed 150 mm.
•
An additional 100 mm of clearance is required for every extra 50 mm of mantle depth, i.e. for a 200 mm deep
mantle the clearance is 500 mm (as shown below).
TV AND ORNAMENTATION WARNING
INSTALLATION OF TV OR ORNAMENTATION ABOVE THE HEATER
The installation of electrical appliances above and in the vicinity of the heater such as, but not
limited to, Plasma TV, LCD TV, Home Theatre Screens, Speakers, etc must comply with their
manufacturers' instructions.
It is the responsibility of the installer/end-user to check the installation instructions of these items
and to ensure the location is suitable.
This caution also extends to, but is not limited to, ornaments such as: Paintings, Prints,
Photographs, Tapestries, Mirrors, Stuffed Animals, etc.
Please note the recommended clearances as per the diagram above.
The temperature of the wall surface directly above the appliance may be elevated and may
discolour paint finishes or distort vinyl wall coverings. For durability of surfaces you should
contact the relevant manufacturer for their specification.
Use either a shelf or mantle below the TV or ornament or alternately you can construct a recess to
mount TV or ornament in.
Check the manufacturers installation instructions for these items and ensure the recess is
suitable.
Rinnai does not take any responsibility for any damage occurring to any items installed above and
in the vicinity of the heater.
750mm
1000mm
400mm
400mm
Maximum
mantle depth
(at 400mm) may
only be 150mm
Maximum
mantle depth
(at 400mm) may
only be 150mm