RIGOL
© 2006 RIGOL Technologies, Inc
User’s Guide for DG2000 Series
5-5
Carrier Waveforms
Sine, Square, Ramp, Arb
Source Internal/
External
Modulating Waveforms 50% duty cycle square (2mHz to 100kHz)
PWM Modulation
Carrier Waveforms
Pulse
Source Internal/
External
Modulating Waveforms Sine, Square, Ramp, Noise, Arb (2mHz to 20kHz)
Deviation
pulse width: 0% to 100%
Sweep
Carrier Waveforms
Sine, Square, Ramp, Arb
Type
Linear or Logarithmic
Sweep Time
1 ms to 500 s ± 0.1%
Source Internal/External/Manual
Burst
Waveforms
Sine, Square, Ramp, Pulse, Noise, Arb
Types
Count (1 to 1,000,000 periods), infinite, gated
Start Phase
-360° to +360°
Internal Period
1
μ
s – 500 s ± 1%
Gate Source
External Trigger
Trigger Source
Internal/External/Manual
Rear Panel Connector
External AM
Modulation
± 5 Vpk = 100% modulation
5k
Ω
input impedance
Input/Output
Frequency Range
10MHz ± 500Hz
Input/Output Voltage
Range
80mV
pp
~10V
pp
/0dBm (typical)
Input/Output
Impedance
2k
Ω
/50
Ω
(typical), AC coupled
Time <1s
External Trigger
TTL-compatible
Trigger Input
Input Level
TTL-compatible
Slope
Rising or falling (selectable)
Pulse Width
> 100 ns
Input Impedance
> 10 k
Ω
, DC coupled