![Right Weigh 201-219-11 Installation & Operation Manual Download Page 27](http://html1.mh-extra.com/html/right-weigh/201-219-11/201-219-11_installation-and-operation-manual_1460676027.webp)
APPENDIX B
27
It is very important that all wiring connections be made watertight.
Connections which are not watertight can allow moisture to travel through
the individual strands of the wires and make it’s way into the scale, causing
permanent damage to the electronics.
After all connections have
been made, heat shrink the
entire group of splices so that
it seals on the outer jacket of
both cables.
With a heat gun or heat torch,
heat the connector until it
shrinks completely around
each wire end. Make sure you
do not burn the wire jacket.
After crimping and heat shrinking
Add heat shrink
After heat shrinking
Crimp each end of the wire
into the connector with a wire
crimp tool (tool not provided).