SENSOR CHECKING / ADJUSTMENT
11
ADJUST STRAIN SENSOR
3
In this example, strain sensor 1 is out of
range and needs to be manually adjusted
until it is within 6.500 and 7.500.
Pushing the bar inward will
lower the number and
pushing the bar outward will
raise the number
NOTE: It takes a very small
amount of force to adjust
the sensor
!
a
With the correct sensor displayed
on the diagnostics screen, loosen
the cover of the proper strain
sensor.
b
While holding the sensor bar in
place, tighten both set screws and
re-check the display. It may take a
moment for the scale to settle on
a number. Repeat process until
range is within 6.500 and 7.500.
c
REPEAT FOR ADDITIONAL SENSORS
4
For multiple sensors, hit the UP ARROW and adjust values until all
sensors are within the range of 6.500 to 7.500.
For sensors that are out of range, repeat step 3.
Find the mounting block with
TWO set screws and loosen one
set screw. GENTLY push the end
of the sensor bar with an
appropriate tool
LOWER NUMBER
RAISE NUMBER