TROUBLESHOOTING
25
APP WON’T CONNECT TO THE GAUGE
Scale is connected to a constant power source:
The gauge should never be connected to a constant power source, rewire
so that it is connected to a switched power source. If the gauge is
powered too long it can stop transmitting a Bluetooth signal and may
need to be disconnected and reconnected to work again.
Scale is already connected to another device:
The scale can only connect to one device at a time
SCALE DOES NOT POWER ON
Scale is not connected to a switched power source of between 9 and 32 volts:
If there is a bad connection in the circuit which causes voltage to drop below 9
volts, the scale will not power on. Test the power source with a voltmeter.
Scale connected directly to battery:
The scale is active anytime it is connected to power, even if the display is off.
To reset it, disconnect and reconnect the power source, wait 10 seconds,
then try again to turn the display on.
Polarity is incorrect:
The red wire must be connected to positive and the black to negative.
CANNOT CHANGE CALIBRATION DATA
The scale has an active user-defined security PIN:
If the scale is protected with a PIN code, the PIN must be entered before
calibration data can be changed. The scale will display “CodE” and the
previously set 5-digit PIN code must be entered to change the data.
GAUGE WILL NOT CALIBRATE LOW/HIGH
Air pressure in the system is not changing:
To enter low or high cal mode, the gauge must see a measurable change in
air pressure. Make sure you calibrate high when the vehicle is near the legal
limit and calibrate low when the truck is empty. Also, be sure the air line is
connected directly to an air bag NOT the main air supply or brake system.
Phone needs to be re-set:
To reset your phone - close the app, turn off Bluetooth, and wait 10 seconds.
Then open the app and turn the Bluetooth back on. Try rescanning for the
scale. If this still doesn’t work, in some cases it is necessary to restart the
phone completely.
Summary of Contents for 201-219-11
Page 1: ...ONBOARD LOAD SCALE EXTERIOR DIGITAL AIR SPRING 2 LOW...
Page 28: ...NOTES 28...