42
8. Finding an reparing malfuncitons
8.2 Repair electrical malfunctions
Warning!
Electrocution hazard!
Only an electrician may repair an electrical malfunction of the machine's elec-
trical equipment if these activities differ from operating tasks. The repair must be
conducted according to electro-technological regulations.
Danger!
Running saw band may cause serious severance injury!
l
Before repairing a malfunction turn off machine at
main switch
so the
motor is not accidentally turned on.
l
The malfunction may only be repaired by one person at a time.
Go through the table from top to bottom when searching for the cause of the malfunction.
Malfunction
Cause
Corrective action
The saw-band motor cannot
be activated, saw-band motor
starts not to run
Main switch turned off
Turn on main switch (see
Chap. 7.3 on p. 33)
The machine is not connected to
power supply.
Connect machine to power
supply (see Chap. 6.5 on p.
29)
Power failure
Re-establish power supply
Circuit breaker triggered in supply
cable
Determine cause and activate
circuit breaker
Power supply is defective.
Request service technician
(see Chap. 8.5 on p. 46)
Safety push buttons
not pressed
Press and hold both
push but-
tons
at the handle
Check phase rotation
If the rotating field is
counter-clockwise turn phase
inverter in the plug
Rotating field monitoring has trig-
gered
Check rotating field of power
line
Rotating field of power line is
incorrectly
Turn phases by phase
inverter in plug
The motor is buzzing after
switching on and does not
come up to rated speed
Missing phase in power supply,
error motor connection, plug,
supply line
Check power supply, check
motor connection
BSM 630
Summary of Contents for BSM 630
Page 2: ...Status 11 2015 Eugen Riexinger GmbH Co KG...
Page 6: ......
Page 24: ......
Page 34: ......
Page 42: ......
Page 62: ...60 9 Maintenance Date Activity Next maintenance Name BSM 630...
Page 68: ...66 11 Annex BSM 630...
Page 69: ...11 Annex 67 11 4 Circuit diagram BSM 630...
Page 70: ......