12
RESIDENCE
SETTINGS MENU TREE STRUCTURE
Below is a list of the parameters that can be programmed; if the adjustment board does not support the relative function, the interface
returns an error message:
The remote control has the function of a machine interface, displaying the system settings and providing access to the parameters.
7KHGLVSOD\QRUPDOO\VKRZVWKHWHPSHUDWXUHRIWKHÀRZVHQVRUXQOHVVWKHUHLVDGRPHVWLFKRWZDWHUUHTXHVWLQSURJUHVVWKHQWKHGRPHV
-
tic hot water probe temperature is displayed; if no key is touched within 10 sec the current time is displayed (backlight unlit).
7KHFRQ¿JXUDWLRQ0(18LVRUJDQLVHGZLWKDPXOWLOHYHOWUHHVWUXFWXUH$QDFFHVVOHYHOKDVEHHQ¿[HGIRUHDFKVXEPHQX86(5OHYHO
always available; TECHNICAL level password protected.
%HORZLVDVXPPDU\RIWKH6(77,1*60(18WUHHVWUXFWXUH
6RPHRIWKHLQIRUPDWLRQPLJKWQRWEHDYDLODEOHGHSHQGLQJRQWKHDFFHVVOHYHOWKHVWDWXVRIWKHPDFKLQHRUWKHV\VWHPFRQ
-
¿JXUDWLRQ
Menu
Parameter
Value
Level
password
Value set
in the factory
Personalised
values
SETTINGS
TIME
USER
TIME PROGRAMM
USER
COMB
GAS TYPE
0 / 1
INSTALLER
0
BOYLER TYPE
1/2/3
SERVICE
1 (25k W)
2 (30k W)
3 (35k W)
COMBUSTION OFFSET
0 / 1 / 2
SERVICE
CONF
HYDRAULIC CONFIGURATION
0 / 1/ / 2 / 3 / 4
INSTALLER
1
WATER TRANSDUCER
0 / 1
SERVICE
1
AUTO WATER FILL ENABLE
0 / 1
SERVICE
0
BEGIN SYSTEM FILLING
NOT AVAILABLE ON THIS MODEL
AIR PURGING CYCLE
0 / 1
SERVICE
1
MIN
INSTALLER
see technical data
table
MAX
INSTALLER
see technical data
table
MAX_CH
MIN - MAX
INSTALLER
see technical data
table
RANGE RATED
MIN - MAX_CH
INSTALLER
see technical data
table
DO_AUX1
0 / 1 / 2
INSTALLER
0
EXHAUST PROBE RESET
0 / 1
INSTALLER
0
CH
HYST ON HIGH TEMP
2 - 10
SERVICE
5
HYST OFF HIGH TEMP
2 - 10
SERVICE
5
HYST ON LOW TEMP
2 - 10
SERVICE
3
HYST OFF LOW TEMP
2 - 10
SERVICE
3
PUMP CONTROL TYPE
0 - 100
INSTALLER
85
CH POSTCIRC
NOT AVAILABLE ON THIS MODEL
LOW NOISE
NOT AVAILABLE ON THIS MODEL
SCREED HEATING
0 / 1
INSTALLER
0
ANTI CYCLE FUNCTION
0 - 20min
INSTALLER
3min
RESET CH TIMERS
0 / 1
INSTALLER
0
MAIN ZONE ACTUATION TYPE
0 / 1
INSTALLER
0
MAIN ZONE ADDR
1 - 6
INSTALLER
3
MAIN ZONE HYDRAULIC CONF
0 / 1
INSTALLER
0
MAIN ZONE TYPE
0 / 1
INSTALLER
0
MAX CH SET
AT: MIN CH SET - 80.5
BT: MIN CH SET - 45.0
INSTALLER
80.5
MIN CH SET
AT: 40 - MAX CH SET
BT: 20 - MAX CH SET
INSTALLER
40
OTR
0 (default) / 1
INSTALLER
0