21
ENGLISH
Domestic hot water REQUEST
, the tap icon blinks:
DAY
OFF
Set the boiler to the OFF status by pressing key 1 until the central
segments are displayed.
4.8
Adjusting the heating water temperature without
an outdoor temperature sensor connected
,I WKHUH LV QR RXWGRRU WHPSHUDWXUH VHQVRU WKH ERLOHU RSHUDWHV DW D ¿[HG
point, the HEATING setpoint in this case can be set on the main page of
the screen.
Pressing the key
C
or
D
displays the current heating setpoint; the value
blinks with a frequency of 0.5 sec ON, 0.5 sec OFF and the icons
and
come on.
+
+
RESET
MENU
D
C
The successive pressing of the key
C
or
D
allows you to set the value of the
heating setpoint within the preset range:
>&&@IRUKLJKWHPSHUDWXUHV\VWHPV
>&&@IRUORZWHPSHUDWXUHV\VWHPV
with steps of 0.5°C.
The level bars beside the heating icon show the setpoint value set with
respect to the operating range:
IRXUEDUVRQ PD[VHWSRLQW
RQHEDURQ PLQVHWSRLQW
Keeping one of the two keys
C
or
D
pressed for longer, the meter increases
the speed of advancement modifying the set value.
If no key is pressed for 5sec, the value set is taken as the new heating
setpoint and the display returns to the main page.
4.9
Adjusting the heating water temperature with an
outdoor temperature sensor connected
If an outdoor temperature sensor is installed and thermoregulation is enabled
SDUDPHWHU 275 WKH GHOLYHU\ WHPSHUDWXUH LV DXWRPDWLFDOO\ VHOHFWHG E\
the system, which quickly adjusts the ambient temperature according to the
variations in the outdoor temperature.
If you want to change the temperature, raising it or lowering it with respect
to the temperature automatically calculated by the electronic board, it is
possible to change the HEATING setpoint as follows:
Press the keys
C
or
D
and select the desired level of comfort within the range
(-5 - +5) (see paragraph
"4.5 Setting the thermoregulation"
).
Note: if an outdoor temperature sensor is connected it is in any event
SRVVLEOHWRKDYHWKHERLOHURSHUDWHDWD¿[HGSRLQWE\VHWWLQJWKHSDUDPHWHU
275 PHQX&+
4.10 Adjusting the domestic hot water temperature
On the main screen, pressing the key
A
rather than
B
displays the current
domestic hot water setpoint, the value blinks with a frequency of 0.5 sec
ON, 0.5 sec OFF and the icons
and
come on.
A
+
+
RESET
MENU
B
The successive pressing of the keys
A
or
B
allows you to set the value
of the domestic hot water setpoint raising or lowering the value within the
preset range in steps of 0.5°C.
The level bars beside the heating icon show the setpoint value set with
respect to the operating range:
IRXUEDUVRQ PD[VHWSRLQW
RQHEDURQ PLQVHWSRLQW
Summary of Contents for RESIDENCE 25 KIS
Page 125: ...125 RESIDENCE 25 KIS 30 35 KIS 18 5 9 23 20 Fig 1 32 35 33 36 34 32 35 33 36 34 ...
Page 137: ...137 RESIDENCE A B C D Fig 21 Fig 22 a b c A B d Fig 23 C ...
Page 138: ......