Accessing the INFO menu from the main page of the interface it is possible
WRGLVSOD\WKH7,0()81&6&5(('
HEATING value regarding the number
of hours that have passed since the activation of the function.
Once activated, the function takes priority, if the machine is shut down by
disconnecting the power supply, when it is restarted the function picks up
from where it was interrupted.
7KHIXQFWLRQFDQEHLQWHUUXSWHGEHIRUHLWKDV¿QLVKHGE\VHWWLQJWKHERLOHU
WRDVWDWXVRWKHUWKDQ2))RUE\VHOHFWLQJ6&5(('+($7,1* IURPWKH
menu CH
.
Note: The temperature and increase values can be set to different values
RQO\ E\ TXDOL¿HG SHUVRQQHO RQO\ LI VWULFWO\ QHFHVVDU\ 7KH PDQXIDFWXUHU
declines all responsibility if the parameters are incorrectly set.
DAY
TIME
TEMPERATURE
1
0
20°C
6
22°C
12
24°C
18
26°C
2
0
28°C
12
30°C
3
0
32°C
4
0
35°C
5
0
35°C
6
0
30°C
7
0
25°C
4.16
&KHFNVGXULQJDQGDIWHUWKH¿UVWFRPPLVVLRQLQJ
After starting up, check that the boiler carries out the start-up procedures
and subsequent shut-down properly.
Check the domestic hot water operation by opening a hot water tap in
6800(5PRGHRU:,17(5PRGH
Check the full stop of the boiler by turning off the system's main switch.
After a couple of minutes of continuous operation, which can be
obtained by turning the system's main switch to "on", setting the boiler
PRGHVHOHFWRUWR6800(5DQGE\NHHSLQJRSHQWKHGRPHVWLFKRWZDWHU
device, the binders and manufacturing residues evaporate and it will be
possible to carry out the check of the combustion.
4.17 Combustion
check
To carry out the combustion analysis, proceed as follows:
set the boiler to the OFF status by pressing button 1
activate the combustion control function by pressing buttons 2+3 for at
least 2sec
2
3
+
+
RESET
MENU
WKH GLVSOD\ VKRZV WKH VFUROOLQJ WH[W &20%867,21 $1$/<6,6 ,1
352*5(66!!DQGWKHLFRQV
,
,
and
come on:
pressing
interrupts the operation
using the
,
keys it is possible to change the speed of the fan
EHWZHHQ0,1DQG0$;FRQ¿UPLQJWKHVHOHFWLRQZLWK
the number of revs set, together with the rpm icon, are shown on the
display for 10sec.
b
With the OT device connected it is not possible to activate the
FRPEXVWLRQ FRQWURO IXQFWLRQ 7R FDUU\ RXW WKH ÀXH JDVHV DQDO\VLV
disconnect the OT connection wires and wait 4 minutes, or else cut
off the electrical supply and reconnect power to the boiler.
b
The combustion analysis function is normally carried out with the
three-way valve positioned on heating. It is possible to switch the
valve to domestic hot water generating a domestic hot water heat
request at maximum output while the function itself is being carried
out. In this case the temperature of the domestic hot water is limited
WRDPD[LPXPRI&:DLWIRUWKHEXUQHUWR¿UH
The boiler will operate at maximum heating output and it will be possible to
regulate the combustion.
5HPRYHWKHVFUHZDQGWKHFRYHURQWKHDLUGLVWULEXWLRQER[
A-B
).
Insert the analysis probe adapter (
D
) located in the documentation
envelope, into the hole for the combustion analysis.
,QVHUWWKHÀXHJDVHVDQDO\VLVSUREHLQWRWKHDGDSWRU
Control the combustion, checking that the CO
2
values match those in
the table.
When the control is completed, remove the analyser probe and close the
combustion analysis sockets with the relative plugs and screw.
Put back and keep the analysis probe adapter supplied with the boiler in
the documentation envelope.
b
If the value displayed is different to that shown in the technical data
WDEOH '2 127 &$55< 287$1<$'-8670(176 2) 7+( *$6
VALVE, ask assistance from the Technical Assistance Centre.
b
The gas valve DOES NOT need adjusting and any tampering with it
causes the boiler to operate irregularly or even not at all.
b
When the combustion analysis is in progress all heat requests are
inhibited and a message is shown on the display.
D