57
BOILER
OFF
HOT WATER ONLY
HEATING AND HOT WATER
OFF
HOT WATER ONLY
HEATING AND HOT WATER
BOILER
11.27 System reset
9
WARNING
: This operation must be carried out only by
professionally qualified personnel. Failure to comply may
result in substantial property damage, severe personal
injury or death.
Whenever necessary, it is possible to restore the factory settings
by carrying out a SYSTEM RESET:
- access the technical parameters as explained in section “11.6
Access to the technical parameters”
- select INSTALLATION with the “up” and “down” buttons,
confirming the selection by pressing the “ENTER” button
PARAMETERS
INSTALLATION
WEATHER COMPENSATION
RANGE RATED
TECHNICAL
INSTALLER
CALIBRATION
RANGE RATED
WEATHER COMPENSATION
PARAMETERS
CALIBRATION
TECHNICAL
INSTALLER
INSTALLATION
- select SYSTEM RESET with the “up” and “down” buttons,
confirming the selection by pressing the “ENTER” button
INSTALL
SENSOR CALIBRATION
INSTALLER
ZONES MANAGER
SYSTEM RESET
ZONES MANAGER
SENSOR CALIBRATION
INSTALL
INSTALLER
SYSTEM RESET
- press “ENTER” button to confirm the system reset or
CANCEL to cancel the operation.
CONFIRM
CANCEL
CANCEL
CONFIRM
Note: after a reset it is necessary to carry out a new
configuration of the system; for details about this
procedure, see the following section.
11.28
System configuration
9
WARNING
: This operation must be carried out only by
professionally qualified personnel. Failure to comply may
result in substantial property damage, severe personal
injury or death.
When restarting after the replacement of the user interface
rather than after a “SYSTEM RESET”, the front control displays
an initial screen with the firmware version. Pressing “ENTER” a
guided procedure is started for configuring the system; select the
desired options with the “up” and “down” buttons, confirming
the selections made with the “ENTER” button:
MULTI ZONE CONTROLLER
REC10 V01.26
PRESS ANY KEY
TO CONTINUE
MULTI ZONE CONTROLLER
PRESS ANY KEY TO
CONTINUE
- LANGUAGE selection:
ENGLISH
FRENCH
- SPANISH
ENGLISH
FRENCH
FRENCH
ENGLISH
- setting TIME and DATE
12
17
:
ENTER TIME AND DATE
TIME & DATE
USE THE ARROWS TO MODIFY
18 / 11 / 2013
ENTER TIME AND DATE
TIME & DATE
USE THE ARROWS TO MODIFY
- setting the operating mode of the user interface:
If this is the system user interface the MASTER option must be
selected.
- configuration selection:
FROM MAIN PCB (Main control board): to recover the current
boiler configuration on user interface MASTER and finish the
operation
NEW: set a new system configuration. Reset all parameters to
factory settings
Summary of Contents for Family PRO 42 IS