Fig. 1 Horizontal flue terminal 2/4” (ø 60-100 mm) PP flue
gases/air
Max length (L)
23 ft (7.01 m)
Terminal length (L1)
2.33 ft (0.711 m)
It is mandatory to use the Ø 2” (60 mm) vent adapter (see “4.2 Boiler box content”),
factory supplied and approved with the boiler, for venting connection
Vent adaptor
Ø 2” (60 mm)
(factory supplied)
fig. 1
Fig. 2 Vertical flue terminal 2/4” (Ø 60-100 mm) PP flue gases/
air for pitched roof
Max length (L)
28 ft (8.53 m)
Terminal length (L1)
4.17 ft (1.27 m)
Vent adaptor Ø 60 mm
(factory supplied)
fig. 2
Fig. 3 Vertical flue terminal 2/4” (Ø 60-100 mm) PP flue gases/
air for flat roof
Max length (L)
28 ft (8.53 m)
Terminal length (L1)
4.17 ft (1.27 m)
fig. 3
Vent adaptor Ø 60 mm
(factory supplied)
Fig. 4 Horizontal flue terminal 3/5” (Ø 80-125 mm) PP flue
gases/air
Max length (L)
60 ft (18.29 m)
Terminal length (L1)
2.42ft (0,74 m)
increaser 2”-3”
fig. 4
V
ent adaptor Ø 3”
80 mm
(factory supplied)
It is mandatory to use the Ø 3” (80 mm) vent adapter (see “4.2 Boiler box content”
page 5), factory supplied and approved with the boiler, for venting connection